Installation Data
1
Mains 220 - 240 V, 16 A; Cu wire-Kabel 3 x 1.5 mm
2.2 kW.
2a Power switch 16 A; 140 cm above floor.
2b Machine connection: Socket incl. earth 60 cm above floor.
3a Water connection: Water consumption 1.9 L/min; water temperature may not be below 5 °C.
3b Water stopcock 3/4 in. washing machine connection.
4
Ventilation of darkroom is necessary.
5
Drainage hose, diameter 50 mm, acid resistant; odor preventor with connection for 10 mm hose.
6
Drainage for developer; hose connection 10 mm. Suitable collection bins must be provided. Local water board
regulations have to be complied with.
7
Drainage for fixer; hose connection 10 mm. Suitable collection bins must be provided. Local water board regulations
have to be complied with.
8
Sink with hot/cold water and a flexible hose; inner dimensions: 60x40x30 cm deep; material: ceramics, stainless steel,
plastic.
9
The replenishment containers can be placed under the processor or can be installed externally.
10 Wall breakthrough for film exit through the wall infeed
film exits into a light room. For the "through-the-wall mounting infeed" alteration, assembly kit no. 1280-0-0000 is
necessary.
11 Wall breakthrough for film exit through the wall output
film exits through the wall to a light room. For the "through-the-wall mounting film output" alteration, assembly kit no.
1281-0-0000 is necessary.

Film exit through the wall

On machines that have the film exit through the wall into a light room, the following modifications have to be made:

Dryer rack

1 Remove the two rollers from position A. To do this, open the bolt
from spring at position 1 and remove the gear from the lower
roller.
2 Move the curved guide bar from position C to position D. To do
this, open bolts 3 and 4.
3 Reinstall the pair of rollers in position B. Mount the spring at
position 2.

Machine cover

The front film exit opening in the machine cover has to be closed
with the screen contained in the assembly kit.
For the "through-the-wall mounting film output" alteration,
assembly kit no. 1281-0-0000 is necessary.
6
2
; Ground-Leakage-Switch 25 A / 30 mA; power consumption
(page
4): The processor is installed outside the darkroom; the
(page
5): The processor is installed inside the darkroom; the