Technical data
5.4 Interfaces and performance features
Resolution absolute position SSI
Max. cable lengths
Signal lines twisted in pairs and shielded.
1)
Because the transmission technology is more robust, the bipolar connection should always be used.
The unipolar connection should only be used if the encoder type does not output push-pull signals.
As of a cable length of 200 m, use a power supply cable with a cable cross-section ≥ 0.75 mm²!
2)
100 m with remote sense
3)
For the cable length, see the diagram "Maximum cable lengths depending on the SSI baud rate for SSI
4)
encoders"
Figure 5-1
Note
The CUA32 control unit adapter also provides an encoder interface for an HTL, TTL or SSI encoder.
The technical data of the CUA32 adapter module can be found in the SINAMICS S120 AC Drive
Manual.
92
For TTL incremental encoder
For HTL incremental encoder
For SSI absolute encoder
Maximum cable length depending on the SSI baud rate for SSI encoders
30 bit
100 m (bipolar signals only)
100 m (for unipolar signals)
300 m (for bipolar signals)
100 m (depending on the baud rate)
Equipment Manual, 07/2021, A5E33446720B