Siemens SIMOTION Equipment Manual page 59

Hide thumbs Also See for SIMOTION:
Table of Contents

Advertisement

X120
Table 4-17
Representation Pin
Reference potential for DI 17+ / DI 19+ / DI 21+ (or F-DI 0 to F-DI 2; second shutdown path)
1)
Functionality depends on the parameterized Safety Integrated functions.
2)
SIMOTION D410-2
Equipment Manual, 07/2021, A5E33446720B
Interface assignment X120
Designation
1
+Temp
2
-Temp
3
F-DI 0
DI 16
2)
4
DI 17+ / EP +24 V3
(Enable Pulses)
5
DI 17- / EP M3 (Ena‐
ble Pulses)
6
F-DI 1
DI 18
2)
7
DI 19+
8
DI 19-
9
F-DI 2
DI 20
2)
10
DI 21+
11
DI 21-
12
M1
4.6 Digital I/Os / temperature sensor / analog input
Notes
Motor temperature sensor input.
Temperature sensors: KTY84–1C130 /
PT1000 / PTC
Measuring current via temperature sensor
connection: 2 mA
Fail-safe digital input 0 or digital inputs 16
and 17
EP function (Enable Pulses) when using Safe‐
ty Integrated Basic Functions via terminal
1)
Fail-safe digital input 1 or digital inputs 18
and 19
1)
Fail-safe digital input 2 or digital inputs 20
and 21
1)
Reference potential for:
DI 16, DI 18 and DI 20 (or F-DI 0 to F-DI 2;
first shutdown path)
DO 16+ (or F‑DO 0)
Interfaces
59