Siemens SIMOTION Equipment Manual page 26

Hide thumbs Also See for SIMOTION:
Table of Contents

Advertisement

Description
2.2 System components
Component
SIMATIC ET 200M
SIMATIC ET 200SP
SIMATIC ET 200S
SIMATIC ET 200AL
SIMATIC ET 200pro
SIMATIC ET 200eco PN
Other PROFINET IO I/O devices
Drive units with PROFINET IO interface
Gateways
Ethernet
The Control Unit can communicate with the following components via the Ethernet interfaces
or be embedded in an automation environment:
Table 2-4
Components on the Ethernet
Component
Programming device (PG/PC)
Master computer
SIMATIC HMI device
26
Function
Modular I/O system for cabinet installation and high channel densities in the SI‐
MATIC S7-300 packaging system.
Finely scalable I/O system for cabinet installation; ET 200SP features a single-cable
and multi-cable connection with push‑in terminals, compact dimensions, high per‐
formance, and low part variety. With the time-based I/O, signals can be recorded or
output to the precise µs.
Finely scalable I/O system for cabinet configuration and particularly time-critical
applications; including motor starters, safety technology and individual grouping of
load groups.
Modular, distributed I/O system with compact I/O modules in IP65/67; simple in‐
stallation in all mounting positions even in small spaces; front and transverse screw
fastenings on flat surfaces or on aluminum supporting channels; flexible connec‐
tion to PROFINET or PROFIBUS or simple integration in SIMATIC ET 200SP.
Modular I/O system with IP65/67 degree of protection for machine-related applica‐
tions with no cabinet; with features such as compact designs, integrated PROFIsafe
safety technology, PROFINET IO connection and live module replacement.
Compact block I/O with IP65/66/67 degree of protection for cabinet-free usage in
machines with M12 connection method. Very rugged and resistant encapsulated
metal enclosure.
... convert speed setpoints into signals for controlling the motor and supply the
power required to operate the motors.
IE/AS-Interface link PN IO for the PROFINET IO gateway to AS-Interface
PN/PN coupler for connecting two PROFINET IO networks
Function
... configures, assigns parameters, programs, and tests using the SIMOTION SCOUT Engi‐
neering System (ES).
... communicates with other devices via UDP, TCP/IP.
... is used for operating and monitoring functions. This is not an essential requirement for the
operation of the SIMOTION D410‑2.
SIMOTION D410-2
Equipment Manual, 07/2021, A5E33446720B

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotion d410-2Simotion d410-2 dpSimotion d410-2 dp/pn

Table of Contents