Interfaces
4.8 Ethernet interface
SIMOTION D410-2 offers the following functions via the Ethernet interface:
• PROFINET basic services (e.g. DCP, LLDP, SNMP)
Although these PROFINET basic services provide uniform functions for the address
assignment and diagnostics, they do not provide PROFINET IO communication for the
connection of drives or I/O modules, for example.
• Communication with STEP 7 and SIMOTION SCOUT
• Communication between SIMOTION and SIMATIC NET OPC
The "SIMATIC NET SOFTNET-S7 (S7-OPC server)" software must be installed on the PG/PC for
this function.
• Connection of HMI systems
• Communication with other devices over TCP/IP or UDP communication
• IT communication (e.g. via SIMOTION IT OPC XML‑DA)
For further information on the software packages, see the SIMOTION PM 21 Catalog.
Interface characteristics
Table 4-25
Characteristic
Connector type
Cable type
Maximum cable
length
Autocrossing
Blanking cover for Ethernet interface included in the scope of delivery;
blanking cover (50 units), article number: 6SL3066‑4CA00‑0AA0
Interface assignment
Table 4-26
Representation
78
X127 interface
Type
RJ45 socket connector
Industrial Ethernet cable
100 m
Yes, i.e. both crossed and uncrossed cables can be used
X127 interface assignment
Pin
Signal name
1
TXP
2
TXN
3
RXP
4
-
5
-
6
RXN
7
-
8
-
Signal type Meaning
Output
Ethernet send differential signal
Output
Ethernet send differential signal
Input
Ethernet receive differential signal
-
Reserved, do not use
-
Reserved, do not use
Input
Ethernet receive differential signal
-
Reserved, do not use
-
Reserved, do not use