Qimarox PD2 User Manual page 43

Pallet dispenser
Table of Contents

Advertisement

10 Pneumatic circuit diagram
10.1 General data
WARNING
Danger potential energy and moving parts. The use of a Safety quick-exhaust
valve (soft-start and quick exhaust valve) PL(d) is mandatory but may not
be in scope of supply of Qimarox.
Qimarox soft –start and quick exhaust valve PL(d):
AE0066989 MS6-SV-1/2-D-10V24P-2M12-AG-WPB
AE0068433 UOS
Note
Set pressure build-up soft-start valve to: ±3s.
The pneumatic diagrams show the following situation: the stack of pallets rests on a conveyor
or surface with the vertical carrier in the mid position and the forks in the pallet stack. This is
the standard situation when stacking and de-stacking pallets.
Air consumption of a standard machine for a pallet capacity of 120 /hour is approximately
1,7m³ (
20°C, 6 bar)
machine.
At a different pallet capacity, the air consumption can be calculated accordingly, or contact
and check with Qimarox.
CAUTION
Safety icons regarding switching off air pressure and venting cylinders need to
be present and clearly visible on all three cylinders. Do not use machine if
icons are not present.
UM Pallet dispenser PD2 v2.0 EN
1lLF
-
. See the specification sheet for the calculated air consumption of the
Pneumatic circuit diagram
43

Advertisement

Table of Contents
loading

Table of Contents