9 Settings
Name
Description
PP018
Minimum pump speed in heating mode [%]
DEAIR
Manual degassing function
CNF
Configuration CN1 and CN2
AD
Searching for devices connected to the boiler PCB
Tab.27
Settings table with eMO Life
Name
Description
CP060 Required ambient temperature (°C) in the zone in
the holiday/antifreeze period
Maximum ambient setpoint temperature (°C) in
reduced mode that enables switching to comfort
CP070
mode with climate control (with outside sensor)
CP080 Temperature (°C) set by SLEEP activity in the zone 16
CP081 Temperature (°C) set by HOME activity in the zone
CP082 Temperature (°C) set by AWAY activity in the zone
CP083 Temperature (°C) set by MORNING activity in the
zone
CP084 Temperature (°C) set by EVENING activity in the
zone
CP085 Temperature (°C) set by CUSTOM activity in the
zone
CP200 Required ambient temperature (°C) for the zone in
manual mode
CP220 Reduced mode heating curve offset (with outside
sensor).
CP240 Adjust the effect of the room unit compared to the
outside sensor
CP250 Correct the temperature measured by the room unit 0
Zone operating mode
CP320
0: Scheduling
1: Manual
2: Off
CP510 Temporary room setpoint per zone
Fireplace mode
CP550
0: Disabled
1: Enabled
Timer programme selected by User
CP570
0: Program 1
1: Program 2
2: Program 3
Boost when starting zone heating: Modify the heat-
ing curve to speed up or slow down reaching of the
required comfort environment
CP730
0: Extremely slowly
1: More slowly
2: Slowly
3: Normal
4: Quickly
5: Extremely quickly
Building cooling speed when the heating is turned
off
CP740
0: Extremely slowly
1: Slowly
2: Normal
3: Quickly
4: Extremely quickly
56
Combi 2
Factory
Minimum
value
85
85
- -
- -
Factory
Minimum
value
6
5
16
5
5
20
5
6
5
21
5
22
5
20
5
20
5
15
15
3
0
-5
0
20
5
0
0
3
2
Maximum Level
100
Installer
Installer
Installer
Installer
Maximum Level
20
User
30
User
30
User
30
User
30
User
30
User
30
User
30
User
30
User
90
Installer
10
Installer
+5
User
User
30
User
User
User
Installer
Installer