9

Settings

Accessing the settings

9.1
Fig.62
Step 2

List of parameters

9.2
Tab.26
Table of parameters
Name
Description
Operation of contact X15 (also see setting AP098)
1: Contact open —> Heating, domestic hot water and
antifreeze disabled (error code H02.10)
AP001
2: Contact open —> Heating, domestic hot water
disabled (error code H02.09)
3: Contact open —> Heating, domestic hot water and
antifreeze disabled (error code E02.13 with reset
request)
Manual heating request enabled based on
implementation of setting AP026
AP002
0: Disabled
1: Enabled
Notification of low pressure in the heating installation
AP006
[bar]
Hours of burner ignition before the maintenance
AP009
notification with AP010=1
Enables/disables maintenance notifications:
0: No notification
AP010
1: Customised notification (depending on settings
AP009 and AP011)
To display/change the list of SERVICE settings, proceed as follows:
press the F3 key, the
turn the
knob until you reach the
turn until you reach the
press the
key to confirm;
if accessing the installer menu, use
the and confirm by pressing the
knob until you reach the desired setting, then press the
turn the
key to confirm;
modify the value of the setting using
the press
to confirm;
press
to exit.
To view/modify the list of settings, it is also possible to connect the
Bluetooth interface to the boiler via the connector X10. Then interface the
handset (SERVICE) to the boiler using the SERVICE TOOL software.
Danger
FOR LOW TEMPERATURE HEATING INSTALLATIONS
MODIFY SETTING CP000 ACCORDING TO THE MAXIMUM
FLOW TEMPERATURE.
Important
The factory settings for certain settings may differ based on the
market the product is destined for.
Factory
value
2
0
0.8
3000
0
symbol on the menu bar starts to flash;
symbol to access user settings,
symbol to access installer settings, then
knob to enter code 0012
key
knob;
Minimum
Maximum Level
0.6
3.0
0
51,000
9 Settings