Download Print this page
3M Versaflo TR-600 Quick Start Manual
Hide thumbs Also See for Versaflo TR-600:

Advertisement

Quick Links

Published: May 2014
Rev: 1 Replaces all previously published guides on this topic until superseded.
The following is a Quick Start Guide for reference purposes only. Before using the TR-600 PAPR, all users must read
and understand the product User Instructions. If you have questions, consult your supervisor or call 3M Technical
Service at 1-800-243-4630 (USA) or 1-800-267-4414 (Canada).
1. Inspect the TR-600 PAPR system. If parts are missing or damaged, replace only with TR-600 replacement parts before
proceeding.
Motor/blower. Inspect for cracks, holes, damage to user interface panel and belt attachments.
Battery pack. Confirm case is intact. Press TEST button on pack to confirm charge is sufficient for duration of
the work period.
Breathing tube. Examine breathing tube for tears, holes or cracks. Bend the tube to verify that it is flexible and not
showing signs of wear. Ensure the o-rings located at both ends of the breathing tube are present and intact.
Filter/cartridge. Closely inspect filter/cartridge plastic housing including the corners and latches, outer
rectangular barrier, and inner circular filter seal gasket for cracks, tears, cuts, distortion, indentations or debris.
Replace filter/cartridge if damaged. If the filter/cartridge has been mishandled or dropped, re-inspect fully. If you
have any concern, contact 3M Technical Service for guidance.
Headgear. Inspect the headgear for tears, cuts, loose stitching, cracks, discoloration or other signs of damage.
2. Assemble TR-600 PAPR system
Attach battery pack to bottom of motor/blower. Pack latches with a distinct click. Gently pull to confirm a secure
connection.
(If being used) Install spark arrestor, then prefilter into filter cover.
Place the filter/cartridge into the filter cover, ensuring bottom latching tab snaps into place. Note: If not using the
filter cover, proceed to next step and attach the filter/cartridge directly to the motor/blower.
Place the hinge side of the filter/cartridge into the motor/blower, then snap latch side into the filter latch.
Filter/cartridge latches with a distinct click. Gently pull to confirm a secure connection.
Attach motor/blower to belt or backpack.
Insert the end of the breathing tube with the two small prongs into slots in the motor/blower air outlet. Twist the
breathing tube ¼ turn to the right (clockwise) to lock.
Attach breathing tube to headgear. Push the QRS end of the breathing tube (blue pinch clip) onto the air inlet of the
headgear. Headgear will secure with a distinct click. Gently pull to confirm a secure connection.
3. Perform flow check.
If installed, remove breathing tube.
Insert air flow indicator TR-971 into the outlet on the TR-600 motor/blower unit.
Start motor/blower. Run for 1 minute.
With the airflow indicator TR-971 in a vertical position, bottom of the floating ball must be at, or above, the
minimum flow level indicated on airflow indicator chart for your
system must not
be used until evaluated and repaired.
Remove air flow indicator TR-971 and perform low flow alarm test per TR-600 User Instructions.
Reattach breathing tube and headgear before use.
4. Don TR-600 PAPR system
Turn on motor/blower by pressing and holding blue on/off button.
Use belt or backpack to attach PAPR to wearer.
Pull headgear over head and adjust.
5. Post Use – Exit work area. Clean and store PAPR following practices established by your employer and in compliance
with the product User Instructions.
Quick Start Guide
3M™ Versaflo™ Powered Air Purifying
Respirator TR-600 Assemblies
Adjust following the user instructions for the specific headgear
'zone'. If not above minimum level, respirator

Advertisement

loading

Summary of Contents for 3M Versaflo TR-600

  • Page 1 The following is a Quick Start Guide for reference purposes only. Before using the TR-600 PAPR, all users must read and understand the product User Instructions. If you have questions, consult your supervisor or call 3M Technical Service at 1-800-243-4630 (USA) or 1-800-267-4414 (Canada).
  • Page 2 Confirm airflow is sufficient. Bottom of the ball Don PAPR. above airflow indicator zone flow level. 3M Personal Safety Division 3M Center, Building 235-2W-70 St. Paul, MN 55144-1000 www.3M.com/PPESafety 3M™ and Versaflo™ are registered trademarks of the 3M Company, and used under license by 3M Canada.
  • Page 3 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: TR-644N TR-6300FC TR-6500FC TR-6700FC TR-616N TR-627 TR-6320N TR-6350N TR-6360N TR-641N TR-6510N TR-6710N-40 TR-6710N-5 TR-6820N 7100019288 7100021092 7100021251 7100021252 7100021253 7100021254 7100021336 7100027408 7100027551 7100028247 7100035759 7100035833 7100035838 7100035844...