AC Power connections

AC Power

The power voltage
The power input voltage of the 908 projector is autoranging between 100V (-10%) and 240V (+6%).
The power input voltage of the vacuum pump and controller unit is not autoranging and will depend on the ordered Baron:
230V Baron (R9040060)
120V Baron (R9040069)
Fuses
The following fuses are used inside the projector (these fuses are located behind the power switch 5.2):
2x T10A (Order number R314521)
1x F10A (Order number R314155)
The following fuse is used inside the control unit (image 5.1):
On a 230V Baron 908 (R9040060) = 230V Control Unit: 1x T1,25A (K314149)
On a 120V Baron 908 (R9040069) = 120V Control Unit: 1x T2,5A (V3141589)
For continued protection against fire hazard: replace with the same type of fuse and refer replacement to qualified service personnel.

Switching on the projector

Switching on
The projector is switched ON and OFF using the power (mains) switch.
Pressed : ON
Not pressed : OFF
OFF
ON
POWER MAINS
REMOTE
image 5.3
Power switch
Stand by indication lamp :
No light up : projector switched off
Green color : projector in Operational mode
Red color : projector is in Standby mode.
When switching on with the power switch, the projector can start now in :
1
Operational mode (picture displayed)
2
Stand by mode
The way of start up depends on the 'Power up' setting in the service mode.
Switching off
Use the same power switch to switch off the projector.
5 - 2
800 periphals
COMM. PORT
PORT 3
IR
RS 232 OUT
RS 232 IN
See installation instructions before connecting to the supply.
Voir la notice d' installation avont de raccorder au réseau.
R
G
B
Comp / H-Sync
V-Sync
PORT 4 / 5
This device complies with part 15 of the FCC rules.
Operation is subject to following two conditions (1).
This device may not cause harmful interference,
and (2) this device must accept any interference that
may cause undesired operation.
VIDEO
S - VIDEO
OFF - ON
75 Ohm
PORT 2
PORT 1
5976418 BARON 908 04122001
OFF - ON
75 Ohm
green: operation
red: standby
PROJECTOR MODE