 Multiple outdoor unit installation
• Provide at least 250 mm of space between the outdoor units if multiple units are installed.
• When routing the piping from the side of an outdoor unit, provide space for piping.
• No more than 3 units must be installed side by side.
When 4 units or more are arranged in a line, provide the space as shown in the following ex-
ample "When an obstruction in the upper space:".
• When the upper space is open:
When there are obstacles at the rear only.
When there are obstacles at the front and
rear.
• When an obstruction in the upper space:
When there are obstacles at the rear and above.
3-1. Models: AOUH30LPAS1 and AOUH36LPAS1
10 (250)
12 (300)
or more
or more
20 (500)
or more
60 (1,500)
or more
Max. 11
(300)
10 (250)
or more
60 (1,500)
or more
10 (250)
or more
- 66 -
When there are obstacles at the front only.
60 (1,500) or more
20 (500) or more
Unit: in (mm)
60 (1,500)
or more
Unit: in (mm)
3. Installation space

Hide quick links: