Fujitsu ASUH30LPAS Service Manual

Wall mounted type
Hide thumbs Also See for ASUH30LPAS:

Advertisement

Quick Links

AIR CONDITIONER
Wall mounted type
INDOOR
OUTDOOR
SERVICE MANUAL
ASUH30LPAS
ASUH36LPAS
AOUH30LPAS1
AOUH36LPAS1
SR_AS053EF_01
2021.12.03

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu ASUH30LPAS

  • Page 1 AIR CONDITIONER Wall mounted type SERVICE MANUAL INDOOR ASUH30LPAS ASUH36LPAS OUTDOOR AOUH30LPAS1 AOUH36LPAS1 SR_AS053EF_01 2021.12.03...
  • Page 2 • Product specifications and design are subject to change without notice for future improvement. • For further details, please check with our authorized dealer. Trademarks ™ FGLair is trademark of Fujitsu General Limited in the United States, other countries or both. ™ Google Play is trademark of Google Inc. ®...
  • Page 3 CONTENTS 1. GENERAL INFORMATION 2. TECHNICAL DATA AND PARTS LIST...
  • Page 5 1. GENERAL INFORMATION 2021.12.03 SR_CH01_AS053EF_01...
  • Page 6: Table Of Contents

    CONTENTS 1. GENERAL INFORMATION 1. Specifications....................01-1 1-1. Indoor unit ........................01-1 1-2. Outdoor unit........................01-3 2. Dimensions....................01-4 2-1. Indoor unit ........................01-4 2-2. Outdoor unit........................01-6...
  • Page 7: Specifications

    1. Specifications 1-1. Indoor unit Wall mounted Type Inverter heat pump Model name ASUH30LPAS ASUH36LPAS Power supply 208/230 V ~ 60 Hz Power supply intake Outdoor unit Available voltage range 187—253 V 8.79 9.67 Rated Btu/h 30,000 33,000 Cooling 2.90—9.50 2.90—10.00...
  • Page 8 Wall mounted Type Inverter heat pump Model name ASUH30LPAS ASUH36LPAS NOTES: • Specifications are based on the following conditions: – Cooling: Indoor temperature of 80°FDB (26.67°CDB) /67°FWB (19.44°CWB), and outdoor temperature of 95°FDB (35°CDB) / 75°FWB (23.9°CWB). – Heating: Indoor temperature of 70°FDB (21.11°CDB) /59°FWB (15.56°CWB), and outdoor temperature of 47°FDB (8.33°CDB) /43°FWB (6.11°CWB).
  • Page 9: Outdoor Unit

    1-2. Outdoor unit Type Inverter heat pump Model name AOUH30LPAS1 AOUH36LPAS1 Power supply 208/230 V ~ 60 Hz Power supply intake Outdoor unit Available voltage range 187—253 V Starting current 13.4 17.8 Cooling 2,187 (3,715) 2,187 (3,715) Airflow rate CFM (m Heating 2,187 (3,715) 2,187 (3,715)
  • Page 10: Dimensions

    2. Dimensions 2-1. Indoor unit ¢ Models: ASUH30LPAS and ASUH36LPAS Unit: in (mm) 45-1/4 (1,150) 13-6/16 (340) 19 (483) 11 (280) 21-7/16 (544) 22-1/16 (560) 45-1/4 (1,150) 20-1/2 (520) 20-1/2 (520) 13/16 (20) 3-9/16 (90) Outline of unit 2-1/2 (64)
  • Page 11  Installation space requirement Provide sufficient installation space for product safety. CAUTION Do not place any other electrical products or household belongings under the product. Conden- sation dripping from the product might get them wet, and may cause damage or malfunction to the property.
  • Page 12: Outdoor Unit

    2-2. Outdoor unit ¢ Models: AOUH30LPAS1 and AOUH36LPAS1 Unit: in (mm) 5-13/16 25-9/16 (650) 5-5/8 (147) (143) 3-way valve (Gas) 3-way valve (Liquid) 1-1/4 (48) Liquid Top view Detail A Detail B 12-5/8 (320) 37 (940) 1-9/16 (40) 9/16 (14) 2-Ф7/8 (22) Cable port 2-Ф7/8 (22)
  • Page 13 2. TECHNICAL DATA AND PARTS LIST 2021.12.03 SR_CH02_AS053EF_01...
  • Page 14 CONTENTS 2. TECHNICAL DATA AND PARTS LIST 1. Precautions....................02-1 2. Indoor unit parts list..................02-2 2-1. Models: ASUH30LPAS and ASUH36LPAS..............02-2 3. Outdoor unit parts list.................02-6 3-1. Models: AOUH30LPAS1 and AOUH36LPAS1 ...............02-6 4. Accessories ....................02-10 4-1. Indoor unit ........................02-10 4-2. Outdoor unit........................02-10 5.
  • Page 15: Precautions

    • Service parts information and design are subject to change without notice for product improve- ment. • For the latest information of the service parts, refer to our Service Portal. https://fujitsu-general.force.com/portal/ • Precise figure of the service parts listed in this manual may differ from the actual service parts. - (02-1) -...
  • Page 16: Indoor Unit Parts List

    2. Indoor unit parts list 2-1. Models: ASUH30LPAS and ASUH36LPAS ¢ Exterior parts - (02-2) - 2-1. Models: ASUH30LPAS and ASUH36LPAS 2. Indoor unit parts list...
  • Page 17 Wireless remote controller ♦ 9334098004 Remote controller holder ♦ 9386986007 Screw cap ♦ 9387072211 Front panel total assy ♦ 9382114039 Intake grille assy ♦ — Front panel — - (02-3) - 2-1. Models: ASUH30LPAS and ASUH36LPAS 2. Indoor unit parts list...
  • Page 18 ¢ Chassis - (02-4) - 2-1. Models: ASUH30LPAS and ASUH36LPAS 2. Indoor unit parts list...
  • Page 19 Control box — — PCB holder A — — Control cover — — Motor cover — — Motor cover — — Cable guide — — Casing — - (02-5) - 2-1. Models: ASUH30LPAS and ASUH36LPAS 2. Indoor unit parts list...
  • Page 20: Outdoor Unit Parts List

    3. Outdoor unit parts list 3-1. Models: AOUH30LPAS1 and AOUH36LPAS1 ¢ Exterior parts and chassis - (02-6) - 3-1. Models: AOUH30LPAS1 and AOUH36LPAS1 3. Outdoor unit parts list...
  • Page 21 Item no. Part no. Part name Service part 9383880001 Top panel assy ♦ 9383779008 Protective net ♦ 9375361013 Net rubber ♦ 313728262708 Thermistor spring A ♦ 9900984038 Thermistor (Heat exchanger temp.) ♦ 9900727154 Thermistor assy (Evaporator and Compressor temp.) ♦ 9383607004 Thermo holder ♦...
  • Page 22 ¢ Compressor - (02-8) - 3-1. Models: AOUH30LPAS1 and AOUH36LPAS1 3. Outdoor unit parts list...
  • Page 23 Item no. Part no. Part name Service part 9380516064 Sound insulator (Top) ♦ 9379647243 Sound insulator (Body) ♦ 9900565091 Thermistor (Outdoor temp.) ♦ 9357804002 Thermostat holder ♦ 9900186029 Pressure switch ♦ 9374425723 4-way valve assy ♦ 9970194016 Solenoid ♦ 9383855115 Refrigerant volume adjustment unit ♦...
  • Page 24: Accessories

    4. Accessories 4-1. Indoor unit ¢ Models: ASUH30LPAS and ASUH36LPAS Part name Exterior Q’ty Part name Exterior Q’ty Operating manual Drain hose insulation Installation manual Cloth tape Wall hook bracket Tapping screw (large) Remote controller Tapping screw (small) Battery Air cleaning filters...
  • Page 25: Refrigerant System Diagrams

    5. Refrigerant system diagrams 5-1. Models: AOUH30LPAS1 and AOUH36LPAS1 Heat exchanger 3-way 3-way (INDOOR) valve valve Pressure switch 4-way valve Strainer Expansion valve Strainer Heat exchanger (OUTDOOR) : Cooling : Heating : Thermistor (Compressor temperature) : Thermistor (Discharge temperature) : Thermistor (Heat Exchanger Med temperature) : Thermistor (Outdoor temperature) : Thermistor (Heat Exchanger Out temperature) : Thermistor (Pipe temperature)
  • Page 26: Wiring Diagrams

    6. Wiring diagrams 6-1. Indoor unit ¢ Models: ASUH30LPAS and ASUH36LPAS - (02-12) - 6-1. Indoor unit 6. Wiring diagrams...
  • Page 27: Outdoor Unit

    6-2. Outdoor unit ¢ Models: AOUH30LPAS1 and AOUH36LPAS1 - (02-13) - 6-2. Outdoor unit 6. Wiring diagrams...
  • Page 28: Pc Board Diagrams

    7. PC board diagrams 7-1. Models: ASUH30LPAS and ASUH36LPAS CONTROL UNIT 30 model: EZ-02109HSE 36 model: EZ-0210AHSE TERMINAL OPTION UNIT (2-WIRE REMOTE CONTROLLER) AWG22 AWG22 BLACK REMOTE CN301 OUTDOOR UNIT CN14 CN300 AWG22 WHITE CONTROLLER AWG26 AWG22 CN13 B07B-PASK-1 POWER SOURCE WHITE B3 ( 5.0 ) B-XASK-1-A...
  • Page 29: Models: Aouh30Lpas1 And Aouh36Lpas1

    7-2. Models: AOUH30LPAS1 and AOUH36LPAS1 INVERTER ASSEMBLY P700 Thermistor Characteristics. 30 model : EZ-0210HUE Temperature 32 °F 68 °F 86 °F Thermistor 36 model : EZ-0210HUE 15.83 k 3.78 k 5.90 k Thermistor ( Heatsink temp. ) 0.43 V 1.01 V 1.42 V DC5V-1 UL1015 AWG20...

This manual is also suitable for:

Asuh36lpasAouh30lpas1Aouh36lpas1

Table of Contents