Fujitsu ASUH30LPAS Design & Technical Manual page 28

Wall mounted type
Hide thumbs Also See for ASUH30LPAS:
Table of Contents

Advertisement

• Forced thermostat off function
Function setting /
60-00 / 2
60-09 / B
60-10 / C
60-11 / D
60-12 / D
¢ Control output function
• Operation/Stop status
Function setting /
60-00 / 2
60-00 / 1
60-09 / B
60-10 / C
60-11 / D
60-12 / D
The output is low when the unit is stopped.
8-4. Details of function
Rotary SW on
External input
and output PCB
External input and
On
Input
Off
On
Compressor
Off
Room temp.
Set temp.
Rotary SW on
External input
and output PCB
Output of indoor unit
External input and
Operation
Indoor unit
Stop
On
CN47
Off
On
CN310
Off
External input
CN313
output PCB
External output
CN47
CN310
output PCB
- 24 -
Input
Command
signal
Thermostat
Off → On
off
Normal
On → Off
operation
Output
Command
signal
Off → On
Operation
On → Off
Stop
Off → On
Operation
On → Off
Stop
8. External input and output

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Asuh36lpasAouh30lpas1Aouh36lpas1

Table of Contents