Cleaning The Field Charger - Trane 4TEE3D01B1000A Installer's Manual

Variable speed – communicating air handlers with integrated whole house air cleaner
Table of Contents

Advertisement

R. CLEANING THE FIELD CHARGER
1. Turn the air conditioning system to OFF at the
Comfort Control. Loosen thumbscrews to remove
the filter panel. Remove the COLLECTION CELL
by pulling forward. See Figure 5, page 4.
2. Use a 5/16" nutdriver to remove the screws holding
the FIELD CHARGER retainer bracket. See Fig-
ures 6 and 7 on page 5.
3. Remove the FIELD CHARGER from the unit. Lay
the FIELD CHARGER on a secured flat surface.
CAUTION
!
FIELD CHARGER PINS ARE SHARP. DO NOT BEND
FIELD
CHARGER
PINS.
GLOVES WHEN HANDLING THE FIELD CHARGER.
4. Wipe down the face plate of the FIELD CHARGER
with a dry shop towel or use a vacuum cleaner.
NOTE: Do NOT disassemble the FIELD CHARGER.
5
Push a block of foam down over the FIELD
CHARGER Pin as in Figure 27.
6. Rotate the foam block on the FIELD CHARGER
Pin. See Figure 28.
7. Use the foam block to clean the faceplate opening
edges.
8. Repeat steps 5, 6 and 7 for each FIELD CHARGER
Pin.
9. Put FIELD CHARGER back into the air handler
and secure the FIELD CHARGER in place with the
retainer bracket. See Figure 6, page 5.
10. Reinstall COLLECTION CELL.
11. Put filter panel back in place.
18-GE15D1-2
WEAR
APPROPRIATE
Installer's Guide
Figure 27. Push block of foam down
over FIELD CHARGER Pin
Figure 28. Rotate block of foam
on FIELD CHARGER Pin
23