Integrated Whole House Cleaner Maintenance; Cleaning The Collection Cell - Trane 4TEE3D01B1000A Installer's Manual

Variable speed – communicating air handlers with integrated whole house air cleaner
Table of Contents

Advertisement

Installer's Guide
P. INTEGRATED WHOLE HOUSE AIR
CLEANER MAINTENANCE
1. For maximum efficiency the COLLECTION CELL
should be inspected and cleaned on a regular basis.
NOTE: A 30 to 90 day cleaning interval is normal for the
COLLECTION CELL and should be adjusted based upon
unit run time and the home environment.
2. The FIELD CHARGER must be removed and
cleaned only by a qualified service professional.
3. The FIELD CHARGER must be cleaned at least
once a year.
4. The FIELD CHARGER may require more frequent
cleaning in homes with high indoor relative humid-
ity (greater than 65% RH).
5. Consult your service professional about cleaning
intervals.
CAUTION
!
High Voltage is present within the air cleaner for opera-
tion. Before removing the Filter Door or Panel, turn the
Comfort Control to the OFF position and disconnect all
sources of power to the unit and wait at least 15 seconds
to allow voltage to discharge.
WARNING
!
RISK OF ELECTRIC SHOCK:
These servicing instructions are for use by qualified
service technician. To reduce the risk of electric
shock, do not perform any servicing other than that
contained in these operating instructions unless you
are qualified to do so.
NOTE: Before cleaning the coil or ducts in the air handler,
remove the COLLECTION CELL and FIELD CHARGER from
the air cleaner. Chemicals used during the cleaning of the air
handler or ductwork can damage the air cleaner compo-
nents and degrade the performance of the air cleaner.
NOTE: In normal operation the air cleaner makes a slight
sound as the air passes through and is cleaned. In some
applications you may notice this sound coming from the
return air vents. If desired, this sound level can be reduced
with minimal impact on air cleaning efficiency by reducing
the power setting of the FIELD CHARGER. The unit is
shipped with the power set at 9.6KV (high), if sound is heard
reduce power level to 8.0KV (low) at the switch on the power
supply. See Figure 26.
22
24 VAC Common
Blue
Return from air cleaner
Green
High voltage power lead
Pink
Figure 26. FIELD CHARGER Power Supply
Q. CLEANING THE COLLECTION CELL
1. Turn the air conditioning system off at the Comfort
Control.
2. Loosen thumbscrews to remove the filter panel.
Remove the COLLECTION CELL by pulling for-
ward. See Figure 5, page 4.
CLEANING
The COLLECTION CELL may be cleaned either by
vacuuming (recommended method) or by washing
with water only.
VACUUM CLEANING
Remove COLLECTION CELL from conditioned
space. Vacuum both sides of the COLLECTION CELL
to clean.
WASHING
Use low-pressure water spray, such as a sink sprayer
or garden hose to clean the COLLECTION CELL.
Some residue may require warm water to be re-
moved.
• Do NOT use soap or detergent in cleaning the COL-
LECTION CELL.
• Do NOT immerse the COLLECTION CELL completely
in water.
• Do NOT place the COLLECTION CELL into a dish-
washer to clean.
• ALLOW THE COLLECTION CELL TO DRY THOR-
OUGHLY BEFORE REINSTALLING.
Slightly tap the COLLECTION CELL to remove wa-
ter retained. Allow the COLLECTION CELL to com-
pletely dry before reinstalling.
24 VAC Hot
Red
LED
High Voltage switch
9.6 to 8.0 KVDC
9.6 KVDC is right side down
8.0 KVDC is left side down
18-GE15D1-2