Trane 4TEE3D01B1000A Installer's Manual page 24

Variable speed – communicating air handlers with integrated whole house air cleaner
Table of Contents

Advertisement

O. CHECKOUT PROCEDURE
After installation has been completed, it is recommended
that the Air Handler be checked against the following
checklists.
"Operational Procedure" for the system installation
can be found in the Outdoor Unit Installer Guide and will
be compatible with this Air Handler.
1. Make sure power is OFF at power disconnect switch ................................................................................ [ ]
2. Check all field wiring for tight connections. See that grounding of unit is in accord with code ............... [ ]
3. Make sure unit suspension (if used) is secure and that there are no tools or loose debris in, around or on top
of the unit ..................................................................................................................................................... [ ]
4. Check all duct outlets; they must be open and unrestricted ...................................................................... [ ]
5. Check drain lines and be sure all joints are tight ....................................................................................... [ ]
6. Make sure secondary drain pan is installed ................................................................................................ [ ]
7. Check power supply for correct requirements per unit nameplate ........................................................... [ ]
8. Inform owner of proper procedure for cleaning COLLECTION CELL ...................................................... [ ]
9. Energize the system and carefully observe its operation; make any necessary adjustment .................... [ ]
10. Instruct owner, engineer (if applicable) on proper operating procedure and leave Use and Care Manual with
owner ............................................................................................................................................................ [ ]
11. Check the integrated whole house electronic air cleaner power output by the Green LED illumination. If the
LED is on, this indicates High Voltage output to the air cleaner .............................................................. [ ]
12. Check to make sure the electronic air cleaner is working ......................................................................... [ ]
a. Turn off Comfort Control
b. Remove air handler top panel
c. Disconnect the 5-pin High Voltage connector to the variable speed motor.
d. Turn the system power ON
e. Turn the Comfort Control to Fan only setting
f. Check for LED illumination on the power supply to the air cleaner. LED illumination indicates High Voltage
power is present to the air cleaner
g. Turn the Comfort Control to OFF
h. Turn the system power OFF
i. Reconnect the 5-pin High Voltage connector to the variable speed motor
j. Replace the air handler top panel
k. Turn the Comfort Control back ON
SUPPLEMENTARY HEATERS CHECKOUT PROCEDURES
IF A HEATER IS USED, SEE "INSTALLATION LIMITATIONS & RECOMMENDATIONS"
1. Be sure the disconnect switch is OFF, and safety label (if any) is attached ................................................ [ ]
2. Check field wiring for tight connections and grounding according to codes .................................................. [ ]
3. Check circuit protection for proper size per nameplate specifications ......................................................... [ ]
4. Check control box panel — in place and secured .......................................................................................... [ ]
NOTE: Operation of heaters must be checked during the operation check of the total system.
Trane
6200 Troup Highway
Tyler, TX 75707
TO DETERMINE IF THE HEATER REQUIRES A SPECIAL CIRCUIT.
The manufacturer has a policy of continuous product and product data improvement, and it reserves the
right to change design and specifications without notice.
WARNING
!
RISK OF ELECTRICAL SHOCK!
Electrical power is present for some of the next steps.
These steps should be performed only by a qualified service
technician. Failure to follow this warning could result in
personal injury, electrical shock, or death.
10/08

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents