16. If side, front or rear return is required, Air Handler must
be elevated or placed on a plenum [TAYPLNM100 for
4TEE3D02, 03, 04, 06, & 08 (23.5" wide), TAYPLNM101
for
4TEE3D01
(21.5"
4TEE3D05, 07, 09, & 10 (26" wide)]. Connecting return
duct directly to the side, front or rear of the cabinet is not
approved.
17. Route refrigerant & condensate drain lines away from Air
Handler so they do not interfere with access panels and
COLLECTION CELL removal.
18. When external accessories are used, the additional
height and width requirements must be considered in the
overall space needed.
19. These units are not approved for outdoor installation.
20. DO NOT use silicon based sealant. This causes a coating
on the FIELD CHARGER pins that will decrease the effi-
ciency of the air cleaner.
NOTE: No atomizing style humidifier is allowed in the return
plenum with the use of this unit.
21. These units are approved for draw-through application only.
22. Flow-through Bypass Humidifiers
Excessive bypass air may cause water blow-off, which
will adversely affect system operation and air cleaner
performance. To verify bypass airflow, follow the Bypass
Humidifier Pre-Installation Checkout and Set-Up Proce-
dures available through your local distributor. Ask for
publication number 18-CH37D1-1.
1) FIELD CHARGER - Charges the con-
taminants
2) COLLECTION CELL - removes and col-
lects very small impurities from the air.
3) Power Supply - the solid state power
supply converts the 24 VAC to the
high-voltage, direct current required to
power the FIELD CHARGER and COL-
LECTION CELL.
4) Safety Switch - cuts off all power to the
FIELD CHARGER and COLLECTION
CELL when disengaged.
Check carefully for any shipping dam-
age. This must be reported to and
claims made against the transportation
company immediately. Check to be
sure all major components are in the
unit. Any missing parts should be re-
ported to your supplier at once, and re-
placed with authorized parts only.
18-GE15D1-2
wide),
TAYPLNM102
1)
2)
Figure 2. Components of the Integrated Whole House Air Cleaner
Steam and Flow-through Fan Power Duct-mounted
Humidifiers. Follow the humidifier installation instruc-
tions. These should only be installed on the supply air
for
side of the system.
23. Unit installation must include either a return air duct or
grille that prevents accidental access to pins. For upflow
open air intake applications that do not have a grille or
return air duct, installation will require the use of either
BAYPLNM120, TASB215, TASB235, or TASB260 de-
pending on cabinet size.
TASB accessories can be purchased from:
Miami Tech Inc.
3611 NW 74 Street
Miami, FL 33147
Phone: 800-339-2290
Fax:: 305-693-6152
www.miamitech.com
TASB215 for use with 21.5" cabinets
TASB235 for use with 23.5: cabinets
TASB260 for use with 26.0 cabinets
24. A PRE-FILTER is not required to be installed with the
air handler containing a Whole House Air Cleaner. If the
use of a PRE-FILTER is desired, it must be installed at
least 6" away from the Whole House Air Cleaner.