Field Wiring Diagrams
Single Stage, Cooling Only
Thermostat
24 VAC HOT
FAN
24 VAC
Common
COOLING
1st STAGE
HEATING
1st STAGE
HEATING
2nd STAGE
2 Stage Indoor Airflow, Cooling Only
Thermostat
24 VAC HOT
FAN
24 VAC
Common
COOLING
1st STAGE
COOLING
2nd STAGE
HEATING
1st STAGE
HEATING
2nd STAGE
18-GF79D1-1A-EN
Air Handler
Outdoor
R
R
G
G
B
B
B
Blue
O
Y
Y1
Y2
Y0
Y
YL/BLK
W1
W1
White
W2
W2
White
BK
WH/BLK
Outdoor
Air Handler
R
R
G
G
B
B
B
Blue
O
Y1
Y1
Y2
Y2
Y0
Y
YL/BLK
W1
W1
White
W2
W2
White
BK
WH/BLK
Single Stage, HP
Thermostat
Air Handler
R
R
24 VAC HOT
G
G
FAN
B
24 VAC
B
Common
Blue
O
O
SOV
COOL/HEAT
Y1
Y
1st STAGE
Y2
Y0
YL/BLK
W1
AUX/EMERGENCY
W1
HEAT 1st STAGE
White
AUX/EMERGENCY
W2
W2
HEAT 2nd STAGE
White
BK
WH/BLK
2 Stage Indoor Airflow, HP
Thermostat
Air Handler
R
R
24 VAC HOT
G
G
FAN
B
24 VAC
B
Common
Blue
O
O
SOV
COOL/HEAT
Y1
Y1
1st STAGE
COOL/HEAT
Y2
Y2
2nd STAGE
Y0
YL/BLK
HEATING
W1
W1
2nd STAGE
White
EMERGENCY
W2
W2
HEAT
White
BK
WH/BLK
Outdoor
R
B
O
Y
X2
Black
Optional
Outdoor
R
B
O
Y
X2
Black
Optional
17