How to Use the Alarm/Control Terminals

These terminals are used for emergency recording, auto time adjustment (Auto Adjust Time), taking measures against power
outages (Shutdown Time), and when installing a buzzer, a lamp, and such an alarming device. They are also used to synchro-
nize with the sequential display changeover.
The terminal pin array and connections are exemplified
below. The connector to be used should be manufactured
according to the pin array.

Pin array

Pin No.
Pin No.
1
Ch 8 alarm output
2
Ch 9 alarm output
3
Ch 10 alarm output
4
Ch 11 alarm output
5
Ch 12 alarm output
6
Ch 13 alarm output
7
Ch 14 alarm output
8
Ch 15 alarm output
9
Ch 16 alarm output
10
NC
11
Alarm display reset input
Emergency recording
12
input
13, 14
Earth (Grounding)
Alarm output for available
15
disk space of device con-
nected to copy port
16
HDD error output
17
Camera error output
18
Error output
End of outage process-
19
ing
20
Time adjustment I/O
Sequence changeover
21
I/O
22
Alarm suspension input
23
Outage detection I/O
External recording mode
24
changeover
25
+5V output
76
Operation
Alarm signal output at an event occurrence
Canceling the alarm display
Starting emergency recording disk space a sig-
nal input
Generation of signal output for disk space alarm-
ing of DVD-RAM, DVD-R, CD-R
Signal output upon detection of HDD error
Signal output upon detection of camera error
Signal output upon detection of unit error
Signal output upon completion of outage pro-
cessing
Time of this unit is adjusted to the preset time
according to the signal input. This signal output is
then generated for the setting time of this unit.
Time of all other units is adjusted to the setting
time of this unit.
Sequence changeover is effected according to
the signal input. Signal output is generated at the
time of sequence changeover.
The state of alarm suspension is assumed
according to the signal input.
Start of outage processing according to the sig-
nal input.
Changeover to the external recording mode
+5V output
!3
q
ALARM/CONTOROL
@5
!4
Open collector output
24 V max., 100 mA
Non-voltage make contact input
–100 mA, 5 V pull-up
Open collector output
24 V max., 100 mA
High (+12V)
30 k 5 V pull-up,
–100mA/make contact
Non-voltage make contact input
–100 mA/5 V pull-up
200 mA max.