I [Comm] Settings For Communication With Other Devices - Panasonic WJ-HD309A Operating Instructions Manual

Digital disk recorders
Table of Contents

Advertisement

I [Comm] Settings for communication with other devices

It is necessary to adjust the communication speed and use
the same communication protocol with external devices
such as a controller when connecting those external
devices to the DATA port or the SERIAL connector
(RS232C).
It is also necessary to perform the settings for the network
such as the IP address and the gateway address when
operating this unit a PC via a network such as a LAN.
These are the descriptions of how to perform the required
settings for communication with external devices.
G [Camera Control] Settings for the communi-
cation method and the cable compensation
for camera control
Select a communication method for each camera channel
to control cameras from the following.
SETUP MENU
Advanced
Camera Control
PS.DATA Setup
RS485 Setup
RS232C Setup
NW Setup 1
NW Setup 2
NTP Setup
Quick Menu
COAX: Controls camera with the coaxial communication
(CAM 1 - 8 CH are available for the WJ-HD316A, CAM
1 - 6 CH are available for the WJ-HD309A)
PSD: Controls camera with the PS·Data. (CAM 1 - 16 CH
are available for the WJ-HD316A, CAM 1 - 9 CH are
available for the WJ-HD309A)
RS485: Controls camera with the RS485 communication.
(CAM 1 - 16 CH are available for the WJ-HD316A, CAM
1 - 9 CH are available for the WJ-HD309A)
OFF: Does not control camera (CAM 1 - 16 CH are avail-
able)
Notes:
• Perform settings according to the cameras connected
to this unit.
• CAM 9-16 control 4 cameras each (only for the WJ-
HD316A).
• When using the coaxial communication to control cam-
eras, connect cameras to the VIDEO IN connectors 1 -
8 for the WJ-HD316A (1 - 6 for the WJ-HD309A) (coaxi-
al communication compatible). When controlling cam-
eras connected to other VIDEO IN connectors with
coaxial communication, use a coaxial communication
unit (WJ-MP204). In this case, select "PSD" for the com-
munication method for the camera channels to be con-
trolled through the coaxial communication unit.
130
System
Recording
Event
Schedule
LIVE
Switcher
Display
Comm
Maintenance
I
Type of Camera Control
CAM
COMP
TYPE
CAM
TYPE
CAM1
S
COAX
CAM9
CAM2
S
COAX
CAM10
PSD
CAM3
S
COAX
CAM11
CAM4
S
COAX
CAM12
CAM5
S
COAX
CAM13
CAM6
S
COAX
CAM14
RS485
CAM7
S
COAX
CAM15
CAM8
S
COAX
CAM16
• To prevent operation mistakes, set the unused camera
channels to off.
It is possible to compensate for the video signal trans-
mission loss from the camera when using the VIDEO IN
connector 1 - 8. (cable compensation)
Perform the settings for the cable compensation
according to the length of cable used.
S: When the length of cable used is shorter than 500 m
M: When the length of cable used is longer than 500 m
and shorter than 900 m
L: When the length of cable used is longer than 900 m
and shorter than 1 200 m
Notes:
• Use 5C-2V cables for the cable compensation.
• Perform the settings for the cable compensation prop-
erly according to the cable length. Otherwise camera
pictures may not be displayed/recorded correctly.
G [PS.DATA Setup] Settings for the PS·Data
Perform the following settings for the PS·Data.
SETUP MENU
System
Recording
Advanced
Switcher
Display
I
Camera Control
Unit Address(System)
I
Unit Address(Controller)
PS.DATA Setup
I
Cascade
RS485 Setup
I
Baud Rate
I
Data Bit
RS232C Setup
I
Parity
NW Setup 1
I
Stop Bit
I
NW Setup 2
Retry Timing
I
Alarm Data
NTP Setup
I
Camera Number Setup
Quick Menu
8 Unit Address (System)
A unit address (System) is a unique number assigning to
PS·Data devices. The addresses must be unique to identify
system devices when connecting multiple devices compati-
ble with PS·Data. Numbers, "001"-"099", are to be assigned
as the unit addresses to the system devices.
8 Unit Address (Controller)
The unit address (controller) is used to control a PS·Data
device connected to this unit. Numbers, "001" - "099" are to
be assigned.
8 Cascade
Select ON or OFF whether or not to use the cascade con-
nection.
Set this to ON when connecting two or more units in the
cascade connection.
ON: Select this when connecting units in the cascade con-
nection.
OFF: Does not function.
Event
Schedule
LIVE
Comm
Maintenance
001
001
OFF
9600
8
NONE
1
OFF
1s