4-12
C
M
ONFIGURING THE
ODULE
Trunk Enable
Use the SET TRUNK MODE command to enable or disable
CoreBuilder 5000 Token Ring trunk ports. The command sequence is:
SET TRUNK {slot} ring_in. { 1 or 2} MODE {enable}
Trunk Network Selection
Use the SET TRUNK NETWORK command to set a trunk port to a
particular backplane or isolated network. The command sequence is:
SET TRUNK {slot}
Trunk Compatibility Mode
Use the SET TRUNK RING_IN/RING_OUT COMPATIBILITY_MODE
command to ensure that the signalling used by a CoreBuilder 5000
trunk port is compatible with the trunk port connected at the other
end of the copper or fiber cable.
Table 4-1
shows the compatibility settings to use when connecting a
CoreBuilder 5000 trunk port:
Table 4-1
CoreBuilder 5000 Compatibility Settings
To Connect CoreBuilder 5000 Modules to:
CoreBuilder 5000 modules
ONline System Concentrator
ONline 5204M-CR
ONsemble
®
IBM
8250 T04MS-CR
IBM 8238 Token Ring Stackable Hub
IBM 8230 CAU
IBM 8228 MAU
IBM 8250 Multiprotocol Intelligent Hub
IBM 8260 Multiprotocol Intelligent Switching Hub 8260
ring_out. { 1 or 2}
ring_in. {1 or 2} NETWORK {token_ring_1..._10}
ring_out. {1 or 2}
Set Compatibility Mode to:
CoreBuilder 5000
ONline
ONsemble
ONsemble
8238
8238
8230
8230
8250
{disable}
{isolated_1..._11}