Table 5-2
outlines possible causes and some solutions for
troubleshooting the Port Status LEDs. A blinking Port Status indicator
signals a problem with a port or link connected to a port.
Table 5-2

Troubleshooting Using the Port Status LEDs

LED
State
Indication
1 blink
Port enabled, but
no station is
detected
(phantom
current is not
detected).
OFF
Port disabled
Possible Cause
Corrective Action
Station not powered. Turn on the PC or other
connected.
Faulty cable.
Replace the cable
No cable connected
Disable the port.
to station.
Station speed does
Check the speed of the
not match the
station and network.
network speed.
Make sure the speeds
match.
Station not inserted
Run your software
on ring.
application to cause the
Token Ring end station to
insert onto the ring.
Port disabled.
Enable port.
Module not
Check the controller
receiving power.
module power LEDs.
Power management
Check hub power
system has powered
management settings (see
down slot.
the DMM User Guide for
more information).
Broken LED.
Press the LED check
button on the controller
module.
Faulty module.
Replace module.