Hardware Reference Manual
GFK-3022E
3.1.2
Flat Wall Mounting Through Wall
to mount the IPC with screws from the wall side, place drill holes in the wall. Refer to the
following figure for the positions for the holes. The thread in the enclosure is a M6 with a usable
thread length of 15 mm (0.60 in). Select the screw length so that a minimum of 10 mm (0.4 in)
thread will be used and torque to 3.5 Nm (30.98 in lb).
Figure 3-3
Mounting
Flat Wall Mounting Through Wall
Mounting
September 2021