Flushing The System; Filling The Water Bath - Cornelius McDonald's QLT-2000 HC Installation & Service Manual

Table of Contents

Advertisement

F
S
LUSHING THE
YSTEM
1. To properly prime the unit with water and remove air pockets from the
system, open the cabinet door and make sure the protective dust cap is
in place on top of the mixing chamber. Close the door and push the
"STOP" Button for a few seconds. Repeat until a steady flow of water is
observed.
NOTE: Water splashing may occur during this purge cycle.
F
W
ILLING THE
ATER
1. Remove the Splash Panel (2 screws next to the drip tray brackets).
2. Release filling tube.
3. Remove the red cap.
4. Install the filling tube onto the RH dispense nozzle.
!
CAUTION:
Make sure that the RH mixing chamber is capped off to prevent the
cabinet from flooding with water
5. Close the cabinet door and push the dispenser button – dispense
water only.
6. Fill the water bath until water flows from the overflow.
7. Remove approx. ½ liter of water. This eliminates dripping from the
overflow when building the ice bank.
8. Install the red cap onto the filling tube and replace the tube into the
bracket.
9. Allow the cabinet to reach 4° C prior to loading any concentrate into
the cabinet. This takes approximately 1 hour.
© 2011-2013, IMI Cornelius Inc.
B
ATH
- 7 -
Quest Elite QLT 2000 HC & Quest Elite QLT 2000
Publication Number: 620054882