Operation; Pressure Relief Procedure - Graco Reactor E-20 Standart Operation

Table of Contents

Advertisement

Operation

Operation
Operation
Operation
Pressure
Pressure Relief
Pressure
Relief Procedure
Relief
Follow the Pressure Relief Procedure
whenever you see this symbol.
This equipment stays pressurized until
pressure is manually relieved. To help prevent
serious injury from pressurized fluid, such
as skin injection, splashing fluid and moving
parts, follow the Pressure Relief Procedure
when you stop spraying and before cleaning,
checking, or servicing equipment.
1. Tap
to turn off the motor.
NOTE: Electric transfer pumps will
NOTE:
NOTE:
automatically turn off with the motor.
2. Tap
,
turn off all heat zones.
3. Relieve pressure in the gun and perform
the gun shutdown procedure. See your gun
manual,
Related Manuals, page 3
4. Engage the gun piston safety lock.
The Fusion AP gun is shown.
32
Procedure
Procedure
, and
.
5. Close the gun fluid inlet valves A and B.
The Fusion AP gun is shown.
6. Shut off the transfer pumps and agitator, if
used.
For
For
For pneumatic
pneumatic transfer
pneumatic
refer to your component manuals. See
Related Manuals, page 3
For
For electric
For
electric transfer
electric
tap
transfer pump power, and
to
off the B-side transfer pump power.
7. Make sure the bleed or circulation lines are
connected and routed to waste containers or
supply tanks. Turn the pressure relief/spray
valves (SA, SB) to pressure relief/circulation
. Make sure the gauges drop to 0.
SA
transfer pumps
transfer
pumps and
pumps
and agitators
and
.
transfer pumps
transfer
pumps (if (if (if necessary)
pumps
necessary),
necessary)
to turn off turn off the A-side
SB
agitators,
agitators
to turn
3A8500C