Resetting

Resetting the unit using the recessed R button on the rear panel can initiate four reset
modes, depending on the length of time the button is pressed and held.
ATTENTION:
Mode
Activation
1 Using an Extron Tweeker or other
small screwdriver, press and hold
in the recessed Reset button for
30 seconds while applying power to
the switcher.
After a mode 1 reset,
NOTE:
update the device with the
latest firmware version.
DO NOT operate with the
firmware version that results
from this mode reset. This
temporarily resets the device
to factory default until power
is recycled. To use factory
default firmware, re-upload
that version.
3 Press and hold down the Reset
button until all front panel LEDs
and the Reset LED blink twice
(approximately 3 seconds) to
confirm the reset. Then, press the
Reset button again momentarily
(less than 1 second).
4 Press and hold down the Reset
button until all front panel LEDs
and the Reset LED blink two times
(at 3 seconds), then two times
again (at 6 seconds) to confirm the
reset. Then, press Reset again
momentarily (less than 1 second).
Review the reset modes carefully. Using the wrong reset mode may result in
unintended loss of flash memory programming, port reassignment, or unit
reboot.
Étudier de près les différents modes de réinitialisation. Appliquer le mauvais
mode de réinitialisation peut causer une perte inattendue de la programmation
de la mémoire flash, une reconfiguration des ports ou une réinitialisation du
processeur.
Reset Modes Summary
The device reverts to the factory
default firmware for a single power
cycle.
All user files and settings (drivers,
audio and video adjustments, IP
settings, and so on) are retained.
NOTE:
the firmware or perform a mode
1 reset by mistake, cycle power
to the device to return to the
firmware version running prior to
the reset.
All front panel LEDs and the Reset
LED blink twice in quick succession
on power up to confirm the reset.
All settings except IP revert to factory
defaults.
IP settings revert to factory defaults.
Port mapping reverts to factory
default.
DHCP turns off.
IP address is set to
192.168.254.254.
Result
If you do not want to update
SW USB Pro Series • Operation
Purpose/Notes
Use mode 1 to revert
to the factory default
version if incompatibility
issues arise with
user-loaded firmware.
Use mode 3 to reset
all settings to factory
defaults while retaining
the IP settings.
The SIS command
equivalent is E ZXXX } .
Use mode 4 to reset
all IP settings back to
factory defaults.
The SIS command
equivalent is
E 1ZQQQ } .