NL Troubleshooting
Malfunction
E:32-00 lights up alternately
or water supply indicator
lights up.
E:92-40 lights up alternately.
E:61-03 lights up alternately.
The water is not pumped
out.
E:61-02 lights up alternately.
40
Cause
The strainers in the water
connection of the supply or
AquaStop hose are
clogged.
Strainers are dirty or clogged.
Drain hose is clogged or
kinked.
Siphon connection is still closed.
Drain pump cover is
loose.
Drain pump is blocked.
Drain pump cover is
loose
Troubleshooting
Turn off the device.
1.
Remove the plug from the socket.
2.
Turn off the tap.
3.
Unscrew the water connection.
4.
Remove the strainer from the inlet hose
5.
Clean the strainer.
6.
Place the strainer in the supply hose.
7.
Screw on the water connection.
8.
Check the water connection for
9.
leaks.
Put the plug back in the
10.
socket.
Turn on the device.
11.
Clean the sieves.
→ "Cleaning sieves", Page 37
Route the drain hose without
1.
kinks.
Remove the remains.
2.
Check the connection to the
siphon and open it if necessary.
▶ Make the cover of the "drain
pump" → Page 52 well fixed.
Clean the drain pump.
→ "Cleaning the drain
pump", page 52
▶ Make the cover of the "drain
pump" → Page 52 well fixed.