Table 5A Wall Thermostats - 2 Stage; Table 5B Wall Thermostats - 3 Stage; Table 6 Humidity Controls; Table 7 Co 2 Controllers - Bard W3SAC-A Installation Instructions Manual

11eer step capacity 2 stage wall mount air conditioner
Hide thumbs Also See for W3SAC-A:
Table of Contents

Advertisement

Part Number
8403-059
2 stage Cool, 2 stage Heat; Electronic Non-Programmable; HP or Conventional (Default: AC); Auto or Manual
(TH5220D1219/U)
changeover
8403-090
2 stage Cool, 3 stage Heat – Heat Pump; 2 stage Cool, 2 stage Heat – Conventional; Programmable/Non-
(T6 Pro)
Programmable Electronic; Auto or Manual changeover
8403-092
2 stage Cool, 3 stage Heat – Heat Pump; 2 stage Cool, 2 stage Heat – Conventional; Programmable/Non-
(T6 Pro Wi-Fi)
Programmable Electronic; Auto or Manual changeover; Wi-Fi
Part Number
8403-060
3 stage Cool; 3 stage Heat; Electronic Programmable/Non-Programmable; HP or Conventional; Auto or Manual
(1120-445)
changeover; Dehumidification Output
3 stage Cool, 3 stage Heat; Programmable/Non-Programmable; HP or Conventional; Auto or Manual Changeover;
CS9B-THOA
Humidity Sensor w/ dehumidification; Motion Sensor w/Intelligent Learning Control; BACnet-compatible
3 stage Cool, 3 stage Heat; Programmable/Non-Programmable; HP or Conventional; Auto or Manual Changeover;
CS9B-THOCA
Humidity Sensor w/ dehumidification; CO
3 stage Cool, 3 stage Heat; Programmable/Non-Programmable; HP or Conventional; Auto or Manual Changeover; Humidity
CS9BE-THOA
Sensor w/ dehumidification; Motion Sensor w/Intelligent Learning Control; BACnet-compatible; Ethernet-compatible
3 stage Cool, 3 stage Heat; Programmable/Non-Programmable; HP or Conventional; Auto or Manual Changeover;
CS9BE-THOCA
Humidity Sensor w/dehumidification; CO
Ethernet-compatible
* Only if no economizer with JADE controller is installed
TABLE 6
Humidity Controls
Part Number
8403-038
SPDT switching, pilot duty 50VA @ 24V;
(H600A1014)
Humidity range 20-80% RH
Electronic dehumidstat SPST closes-
8403-047
on-rise; Humidity range 10-90% with
(H200-10-21-10)
adjustable stops
TABLE 7
CO
Controllers
2
Part Number
CO
ventilation control with digital display.
2
8403-056
Normally Open SPST (Default: Close at
800ppm)
Normally Open SPST relay closes-on-rise
24V dual wave length sensor. Default setting
8403-096
950ppm, adjustable to 0-2000ppm
Default off setting 1000ppm, adjustable to
0-200 ppm can be calibrated
Manual 2100-720E
Page
20 of 42
Wall Thermostats – 2 Stage (No Balanced Climate)
Wall Thermostats – 3 Stage (Balanced Climate)*
Predominate Features
Predominate Features
TABLE 5A
Predominate Features
TABLE 5B
Predominate Features
Sensor; Motion Sensor w/Intelligent Learning Control; BACnet-compatible
2
Sensor; Motion Sensor w/Intelligent Learning Control; BACnet-compatible;
2
Transformer
VA
55
TABLE 8
Thermostat Wire Size
FLA
Wire Gauge
18 gauge
16 gauge
2.3
14 gauge
12 gauge
Maximum
Distance
In Feet
60
100
160
250