• Turn OFF all power to the Automatic Door if a Safety System is not working.
• Instruct the Owner to keep all power turned OFF until corrective action can be achieved by a NABCO
Entrances trained technician. Failure to follow these practices may result in serious consequences.
• NEVER leave a Door operating without all Safety detection systems operational.

Table of Contents

CHAPTER 1: WARNING LABELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
CHAPTER 2: GENERAL SAFETY RECOMMENDATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
CHAPTER 3: SCOPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SECTION 3.1: To the Customer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SECTION 3.2: Objective . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
CHAPTER 4: GETTING STARTED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SECTION 4.1: Service Availability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SECTION 4.2: Safety Standard Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SECTION 4.3: Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SECTION 4.4: Information Provided by Door Supplier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
CHAPTER 5: GENERAL SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
CHAPTER 6: OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
CHAPTER 7: DAILY SAFETY CHECKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Section 7.1: Presence Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Section 7.2: Knowing Act Activation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Section 7.3: Slide Door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Section 7.4: Breakout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
CHAPTER 8: SAFETY DECALS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
NABCO hours of Operation: Monday to Friday 8:00 a.m.- 4:30 p.m. (Central Time)
ICU 2400 Automatic Sliding Door
OWNER'S MANUAL
A Founding Member of: AAADM
WARNING
S82 W18717 Gemini Drive
Muskego, Wisconsin 53150
Phone: (877) 622-2694
Fax: (888) 679-3319
www.nabcoentrances.com
Technical Support: (866) 622-8325
P/N C-00394
Rev. 2/28/22

Advertisement

loading

Summary of Contents for Nabco ICU 2400

  • Page 1: Table Of Contents

    • Turn OFF all power to the Automatic Door if a Safety System is not working. • Instruct the Owner to keep all power turned OFF until corrective action can be achieved by a NABCO Entrances trained technician. Failure to follow these practices may result in serious consequences.
  • Page 2: Chapter 1: Warning Labels

    A156.38 (Low Energy Power Operated Sliding and Folding Doors). CHAPTER 4: GETTING STARTED ICU 2400 Automatic Slide Doors are available in a single slide configuration only. As a rule, the ICU 2400 Automatic is furnished as a complete package. This package typically includes: an Operator, Controller, Header, Track, Carrier Wheels, (1) Slide Door, (1) Sidelite, (2) Jamb Tubes, (1) Lock and an Activation/Safety System.
  • Page 3: Section 4.1: Service Availability

    Warranty will not obligate NABCO Entrances or damages resulting from such alterations, misuse, or acts of God, or acts of terrorism. SECTION 4.4: Information Provided by Door Supplier Instruction on how to conduct the Daily Safety Check.
  • Page 4: Chapter 6: Operation

    The NABCO Entrances recommendation is for Presence Sensors to detect both moving and non-moving objects in the path of the door and signal the Control Unit accordingly. ICU 2400 Automatic Slide Doors are typically installed with (1) Sensor on each side of the Header. In the event a Slide door is still in the process of closing, and an object is detected within a minimum of (24) inches from the door, the Inactive Sensor will fully re-open the door.
  • Page 5: Section 7.2: Knowing Act Activation

    ICU 2400 Automatic Sliding Door Owners Manual Rev. 2-28-22 P/N C-00394  7.1.2 Types of Sensor Malfunctions Attention: Examples shown only illustrate some types of causes for Sensor Malfunctions (not all). An object placed within the Presence Detection Zone that Sensor is exposed to: Steam, Exhaust Fume, Insects, Heavy...
  • Page 6: Section 7.3: Slide Door

    CAUTION CAUTION NABCO Entrances trained technician, or service provider. In order to guarantee reliability of the installation, any components showing signs of wear must be replaced as a preventive measure. Attention: In the event any type of object needs to be removed from the Sensor Detection Zone (vicinity), the Sensor will keep the door open until it “relearns”...
  • Page 7: Chapter 8: Safety Decals

    ICU 2400 Automatic Sliding Door Owners Manual Rev. 2-28-22 P/N C-00394 3. Fully Close both Doors. 4. Call your supplier if detailed information is needed. Example Shown: Right Hand Unit FO Sidelite Panel Slide Door U lity Breakout Side of Door Figure 2 ICU 2400A Breakout...