Quick Links

• Turn OFF all power to the Automatic Door if a Safety System is not working.
WARNING
• Instruct the Owner to keep all power turned OFF until corrective action can be achieved
• NEVER leave a Door operating without all Safety detection systems operational.

Table of Contents

CHAPTER 1: SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
CHAPTER 2: SCOPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SECTION 2.1: To the Installer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SECTION 2.2: Objective . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
CHAPTER 3: FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
CHAPTER 4: SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SECTION 4.1 General Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SECTION 4.2 Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SECTION 4.3 Output Power Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
CHAPTER 5: 120 VAC GENERAL WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
CHAPTER 6: THE OPUS CONTROL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
CHAPTER 7: THE ROTARY DIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
CHAPTER 8: LCD CATAGORY SCREENS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
SECTION 8.1: Level One: Specification Screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
SECTION 8.2: Level Two: Access Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
SECTION 8.3: Level Three and Four: Setting Category and Menu Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
CHAPTER 9: COMMON PROGRAM ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
SECTION 9.1: Stroke Learning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
SECTION 9.2: Movement Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
CHAPTER 10: FOLD DOOR WIRING DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
CHAPTER 11: SWING DOOR WIRING DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
CHAPTER 12: TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
SERVICE PARTS: OPUS SIDE LOAD UNITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
SERVICE PARTS: OPUS BOTTOM LOAD UNITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Nabco Entrances Inc. S82 W18717 Gemini Drive Muskego, Wisconsin 53150
Phone: (877) 622-2694 Fax: (888) 679-3319 www.nabcoentrances.com
NABCO hours of Operation: Monday to Friday 8:00 a.m.- 4:30 p.m. (Central Time)
by a NABCO trained technician. Failure to follow these practices may result in serious
consequences.
Opus Control Wiring and Programming
Installation Manual
P/N C-00139 Rev 10-20-17
1 of 32

Advertisement

Table of Contents
loading

Summary of Contents for Nabco Opus Control

  • Page 1: Table Of Contents

    WARNING • Instruct the Owner to keep all power turned OFF until corrective action can be achieved by a NABCO trained technician. Failure to follow these practices may result in serious consequences. • NEVER leave a Door operating without all Safety detection systems operational.
  • Page 2: Chapter 1: Safety

    All electrical troublshooting or service must be performed by trained, qualified electrical CAUTION technicians and comply with all applicable governing agency codes. Do Not touch other parts of the Opus Control board with a screwdriver or anything else metal. CAUTION Damage to electrical circuitry may occur.
  • Page 3: Chapter 2: Scope

    NABCO trained technicians. If after troubleshooting a problem, a satisfactory solution cannot be achieved, please call Nabco Entrances at 1-877-622-2694 between 8 am – 4:30 pm Central time for additional assistance.
  • Page 4: Section 4.3 Output Power Guidelines

    Auxiliary Equipment TOTAL current draw from the Opus Control must not exceed 0.7A when providing power to: If TOTAL current draw exceeds 0.7A the installer must utilize an auxiliary power supply such as the NABCO Transformer 24 VAC, P/N A-01185.
  • Page 5 Attention:  Insert all Incoming 120 VAC Power wires into the pre drilled Electric Service Access Hole located at the left or right side of Header End Cap. Attention:  Electrical circuit to Nabco operator must not be not shared with other equipment such as lighting, cash registers, or any device that might cause electrical interference on the circuit Note: It is recommended for the Installer to house all Incoming 120 VAC wires within an Electrical Conduit.
  • Page 6: Chapter 6: The Opus Control

    CHAPTER 6: THE OPUS CONTROL The Opus Control is used to power and control operating characteristics of the door with the use of harnesses and wiring. Note: When the LCD Screen is LIT, the Hold Close feature is disabled. When the LCD screen is OFF, the Hold Close feature is enabled.
  • Page 7: Chapter 8: Lcd Catagory Screens

    DN 1241 Level One screens are used to inform the User all specifications that have already been programmed into the Opus Control. If a specification needs to be changed, the User must reprogram the Opus Control within the Level Three screen, or Level Four screen.
  • Page 8: Section 8.2: Level Two: Access Screen

    This Passcode cannot be changed, but can be turned OFF and ON. Attention:  Do Not activate Passcode (0045) until programming of the Opus Control is complete. Failure to do so, will force the User to enter (0045) each time a change is made.
  • Page 9: Section 8.3: Level Three And Four: Setting Category And Menu Items

    www.NabcoEntrances.com OpusControlWiringandProgrammingInstallationManual Rev. 10-20-17 P/N C-00139  8.2.2 Cancel Passcode or Reset to Default LEVEL 2 Reset to Default Set Reset to Default Set Reset to Default Set Passcode 0 0 0 Reset to Default Set If you don’t know If you don’t know If you don’t know Stroke Learning Short...
  • Page 10 Opus Control Wiring and Programming Installation Manual www.NabcoEntrances.com P/N C-00139 Rev 10-20-17 Base Settings Setting Category Menu Item Default Action   Door Hand Left Left From the Exterior Side of Building, determine which Handing to   (for Fold Doors) Right...
  • Page 11   Overlap Sim Pair Overlap Sim Pair is for an Astragal Application.   Opus Control connected to door that must open first must:  1. Have activation signals connected to it  2. Be set to “Overlap Sim Pair”   The delayed control will be set to “Normal Sim Pair”...
  • Page 12   Overlap Sim Pair Overlap Sim Pair is for an Astragal Application.   Opus Control connected to door that must open first must:  3. Have activation signals connected to it  4. Be set to “Overlap Sim Pair”   The delayed control will be set to “Normal Sim Pair”...
  • Page 13 www.NabcoEntrances.com OpusControlWiringandProgrammingInstallationManual Rev. 10-20-17 P/N C-00139 Input Settings Parameter Terminal Range Default Sequential Input Takes on activation to open then another to close door Input 62 Terminal 4 Open Slow Exterior Causes slow opening of the door Activation Safety with Lockout Swing side header mounted sensor input Continuous Safety Swing side door mounted sensor input...
  • Page 14: Chapter 9: Common Program Adjustments

    Opus Control Wiring and Programming Installation Manual www.NabcoEntrances.com P/N C-00139 Rev 10-20-17 History Settings Parameter Description   Operation Cnt Indicates number of Door open cycles.   Updated every 100 door cycles. Open Recycle Cnt Indicates number of times the Door reversed direction during Opening cycle after sensing:  ...
  • Page 15: Section 9.3: Recycle Count "Reset

    www.NabcoEntrances.com OpusControlWiringandProgrammingInstallationManual Rev. 10-20-17 P/N C-00139 SECTION 9.3: Recycle Count “Reset” LEVEL 2 LEVEL 1 LEVEL 3 Passcode 1. Rotate Dial to select Push and Hold Go to Se ng menu UNIT SPECS Se ng Category Rotary Dial (2 Sec.) "Go to Se ng menu". Stroke Learning 2.
  • Page 16: Chapter 10: Fold Door Wiring Diagrams

    Opus Control Wiring and Programming Installation Manual www.NabcoEntrances.com P/N C-00139 Rev 10-20-17 CHAPTER 10: FOLD DOOR WIRING DIAGRAMS SECTION 10.1: Switches and Sensors 16 of 32...
  • Page 17 www.NabcoEntrances.com OpusControlWiringandProgrammingInstallationManual Rev. 10-20-17 P/N C-00139 SECTION 10.2: Switches and Sensors with Monitoring 17 of 32...
  • Page 18: Chapter 11: Swing Door Wiring Diagrams

    Opus Control Wiring and Programming Installation Manual www.NabcoEntrances.com P/N C-00139 Rev 10-20-17 CHAPTER 11: SWING DOOR WIRING DIAGRAMS SECTION 11.1: Activation 12VDC +12VDC Common for 12V and Signals Interior Ac va on Exterior Ac va on/Programmable Input Swing Door Con nuous Safety (door mounted, swing side Safety Sensor)
  • Page 19 www.NabcoEntrances.com OpusControlWiringandProgrammingInstallationManual Rev. 10-20-17 P/N C-00139 SECTION 11.2: Activation using ON/OFF/Hold-Open Switch 12VDC +12VDC Common for 12V and Signals Interior Ac va on Exterior Ac va on/Programmable Input Swing Door Con nuous Safety (door mounted, swing side Safety Sensor) Slide Door Holding Beam Swing Door Safety with Lockout (overhead, swing side safety sensor) Slide Door...
  • Page 20 Opus Control Wiring and Programming Installation Manual www.NabcoEntrances.com P/N C-00139 Rev 10-20-17 SECTION 11.3: Safety 20 of 32...
  • Page 21 www.NabcoEntrances.com OpusControlWiringandProgrammingInstallationManual Rev. 10-20-17 P/N C-00139 SECTION 11.4: Safety with Monitoring 21 of 32...
  • Page 22 Opus Control Wiring and Programming Installation Manual www.NabcoEntrances.com P/N C-00139 Rev 10-20-17 SECTION 11.5: Lock 22 of 32...
  • Page 23 www.NabcoEntrances.com OpusControlWiringandProgrammingInstallationManual Rev. 10-20-17 P/N C-00139 SECTION 11.6: Standard Wiring for Single Full Automatic 23 of 32...
  • Page 24 Opus Control Wiring and Programming Installation Manual www.NabcoEntrances.com P/N C-00139 Rev 10-20-17 SECTION 11.7: Single Full Automatic with Monitoring 24 of 32...
  • Page 25 www.NabcoEntrances.com OpusControlWiringandProgrammingInstallationManual Rev. 10-20-17 P/N C-00139 SECTION 11.8: Standard Wiring for Simultaneous Pair Full Automatic ON/OFF/HOLD-OPEN SWITCH P.N. A-00805 Hold Open BLUE BLACK WHITE PWR+ PWR- N.O. Activation Sensor PWR+ PWR- N.O. Overhead Swing Side Sensor (if used) Door Mounted Approach Side Sensor N.O.
  • Page 26 Opus Control Wiring and Programming Installation Manual www.NabcoEntrances.com P/N C-00139 Rev 10-20-17 SECTION 11.9: Simultaneous Pair Full Automatic with Monitoring DN 1660 26 of 32...
  • Page 27 BLUE BLACK WHITE BLUE BA (break-out input) must be set to N.C. on the Opus Control (is by default). Panic Latch must be mounted so that the: • Switch is open when the Door is broken out. • Closed when not broken-out...
  • Page 28 Opus Control Wiring and Programming Installation Manual www.NabcoEntrances.com P/N C-00139 Rev 10-20-17 SECTION 11.11: Other Break-out, Used mainly for sliding doors, can be used for ON/OFF with swing doors. Sequential activation. Signal to open, Signal to close. 10 H Programmable input 11 M0 Mode 0, When grounded, puts door into "One-Way"...
  • Page 29: Chapter 12: Troubleshooting

    www.NabcoEntrances.com OpusControlWiringandProgrammingInstallationManual Rev. 10-20-17 P/N C-00139 CHAPTER 12: TROUBLESHOOTING Programming Tips Action   To copy settings from one Software Revision (up to 19) Sim Pair Control to the other • On the Control being programmed, after other settings are complete, go to “SimPair Setting” Sim Pair Control under “Optional Settings”.
  • Page 30 Notice: If after troubleshooting a problem, and a satisfactory solution cannot be achieved, please call Nabco Entrances at 1-877-622-2694 between 8 am – 4:30pm Central time for additional assistance. DO NOT leave any problem unresolved. If the door cannot be repaired immediately, turn off the door and leave it inoperable until repairs can be made.
  • Page 31: Service Parts: Opus Side Load Units

    SERVICE PARTS: OPUS SIDE LOAD UNITS DN 1321 Side Load Unit Item Part Finish/Sizes/Notes Description T-00365 WASHER:5/32IDx3/4ODx.020THK:POLYETHYLE M-01546 “CONTROLLER,OPUS” V-00552 Used on Opus Control FUSE;5A;GMA;5X20mm T-00335 SHCS:10-24x0.313L. A-01097 Used on GT710/8710 only CONTROLLER,710,OPUS A-01003 Not used on GT710/8710 “BRAKE MODULE,OPUS” V-00288 Used on Brake Module...
  • Page 32: Service Parts: Opus Bottom Load Units

    Opus Control Wiring and Programming Installation Manual www.NabcoEntrances.com P/N C-00139 Rev 10-20-17 SERVICE PARTS: OPUS BOTTOM LOAD UNITS DN 1320 Bottom Load Unit Item Part Finish/Sizes/Notes Description M-01072 HARNESS,POWER,MAGNUM BOARD T-00251 Sim Pair Only WIRE,20 AWG,BLUE M-01162 HARNESS,MICROSWITCH,MAGNUM A-01000 GT300/400/500/600 only “HARNESS,MOTOR,OPUS CONTROL...