Advertisement

G Y R O T E C H
NABCO ENTRANCES Inc.
S82 W18717 Gemini Drive
P.O. Box 906
Muskego, WI 53150
Phone: 877-622-2694
Fax:
888-679-3319
www.nabcoentrances.com
Model 710 Swing Door System
DN0011
Do not install, operate or service this product unless you have read and understand the Safety Practices,
Warnings, Installation and Operating Instructions contained in this manual. Failure to do so may result
Part Number 15-10677
August 23, 2004 Revision
NABCO
ENTRANCES INC
Automatic
Entrance
Systems
Retrofit Kit Manual
Low Energy Operator
WARNING
in property damage, or bodily injury.
877-622-2694
www.nabcoentrances.com
Model 710 Swing Door System
Magnum Board IV.
Retrofit kit (Old Casting)
INSTALLATION MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Nabco 710

  • Page 1 Model 710 Swing Door System Magnum Board IV. Retrofit kit (Old Casting) Automatic Entrance G Y R O T E C H Systems NABCO ENTRANCES Inc. S82 W18717 Gemini Drive P.O. Box 906 Muskego, WI 53150 Phone: 877-622-2694 Fax: 888-679-3319 www.nabcoentrances.com...
  • Page 2 6. Replacement labels and literature may be obtained from local NABCO Entrances Inc. distributors. If the name of the local distributor is unknown, contact NABCO Entrances Inc. at (877-622-2694) for assistance. 7. Do not place finger or uninsulated tools inside the electrical control box. Touching wires or other parts inside the enclosure may cause electrical shock, serious injury or death.
  • Page 3: Table Of Contents

    Model 710 Swing Door System Contents Overview Specifications Handing Requirements Hardware Kit List Magnet Switch Assembly Single Door Conversion Simultaneous Pair Conversion Hydraulic Closer Hydraulic Closer Adjustment Setting Back Check and Door Closed Switches 14~18 Simultaneous Pair Installations Control Switches...
  • Page 4: Overview

    Standard 156.19 usually covers this type of door. Other local standards or codes may apply. Use them in addition to the ANSI Standard. The GT 710 is listed with the Underwriters Laboratory and is identified as such on the label.
  • Page 5: Specifications

    Model 710 Swing Door System Table 1 – Comparison of Magnum IV to the original GT710 Controller Magnum IV Board GT710 Controller Adjustable opening speed. Adjustable opening speed. Adjustable current limit/door block Adjustable current limit/door block trip. trip. Adjustable activation timer (0 to 60...
  • Page 6: Handing Requirements

    Model 710 Swing Door System Handing Requirements The type of door will determine whether a left-hand or a right-hand operator is required. Figure 2 can be used to determine which unit is required. RIGHT HAND LEFT HAND OUT-SWING OUT-SWING (RH)
  • Page 7: Hardware Kit List

    Model 710 Swing Door System Hardware Kit List This kit has been shipped with the following installation hardware. MAGNUM IV RETRO FIT for SINGLE – P/N 11-10361-01 MAGNUM IV RETRO FIT for SIM.PAIR – P/N 11-10361-02 Part # Part Description...
  • Page 8 Model 710 Swing Door System S T O P O P E N B C H K TDAS T D P G L C H K C L O S E Fuse 2: 0.5A 24 VAC L E D SIGNAL...
  • Page 9 Model 710 Swing Door System Figure 4 – Magnetic Switch assembly NABCO - 9 - ENTRANCES INC 877-622-2694 www.nabcoentrances.com...
  • Page 10 Model 710 Swing Door System Figure 5 – Single Door Conversion of GT710 NABCO - 10 - ENTRANCES INC 877-622-2694 www.nabcoentrances.com...
  • Page 11 Model 710 Swing Door System Figure 6 – Simultaneous Pair Door Conversion of GT710 NABCO - 11 - ENTRANCES INC 877-622-2694 www.nabcoentrances.com...
  • Page 12: Hydraulic Closer

    Model 710 Swing Door System Hydraulic Closer The door closer has an adjustment for “opening force” when the doors is used in a manual mode that is preset at the factory. The setting is based on a 30-inch exterior door and a 38-inch interior door. Adjustments are made using an allen wrench as shown in Figure 7.
  • Page 13: Hydraulic Closer Adjustment

    Model 710 Swing Door System Door Closing Adjustment Procedure The hydraulic closer must be operating properly BEFORE the Magnum control is adjusted. Warning: Improperly installed or adjusted closers may cause property damage or personal injury. Please follow these instructions carefully.
  • Page 14: Setting Back Check And Door Closed Switches

    Model 710 Swing Door System The GT 710 has two magnetic switches that control the back check location Setting Back Check and and monitors the door closed position. The back check magnet must be installed Door Closed Switches before the unit is tested. It signals the motor to slow down so the door does not slam open.
  • Page 15 Model 710 Swing Door System Figure 10 – Left Hand Outswing NABCO - 15 - ENTRANCES INC 877-622-2694 www.nabcoentrances.com...
  • Page 16 Model 710 Swing Door System Figure 11 – Right Hand Outswing Door Shown NABCO - 16 - ENTRANCES INC 877-622-2694 www.nabcoentrances.com...
  • Page 17 Model 710 Swing Door System Figure 12 – Right Hand Inswing Door Shown. NABCO - 17 - ENTRANCES INC 877-622-2694 www.nabcoentrances.com...
  • Page 18 Model 710 Swing Door System Figure 13 – Left Hand Door Inswing Shown NABCO - 18 - ENTRANCES INC 877-622-2694 www.nabcoentrances.com...
  • Page 19: Simultaneous Pair Installations

    Refer to Section 6 of ANSI A156.19 Standard for Power Assist and Lower Energy Power Operated Doors. Decals have been provided with the GT 710 to comply with all the installation applications described in ANSI A156.19.
  • Page 20 Model 710 Swing Door System Troubleshooting Symptom Action/Cause Solution Operator does not function. 1. Check Fuse 2 (F2). 1. Replace fuse. 2. Check for 120 VAC at 2. Check incoming power. If power is good, check connector J5. connection to motor. Replace motor if necessary.
  • Page 21 Model 710 Swing Door System Appendix A EXCERPTS FROM ANSI/BHMA A156.19 – 1997 REQUIREMENTS FOR LOW ENERGY SWINGING POWER OPERATED DOORS OR LOW ENERGY SWINGING POWER OPEN DOORS Opening Time 4.1.1 Doors shall be field adjusted so that opening time to back check or 80 degrees, which ever occurs first, shall be 3 seconds or longer as required in Table 1.
  • Page 22 Model 710 Swing Door System Table 1 Minimum Opening Time to Back Check or 80 degrees, which ever occurs first, or Minimum Closing time from 90 degrees to Latch Check or 10 degrees. Back check shall not occur before 60 degree opening.

Table of Contents