Full Automatic and Low Energy Power Operated Doors
(American Association of Automatic Door Manufacturers)
• Turn OFF all power to the Automatic Door if a Safety System is not working.
• Instruct the Owner to keep all power turned OFF until corrective action can be achieved by a NABCO
trained technician. Failure to follow these practices may result in serious consequences.
• NEVER leave a Door operating without all Safety detection systems operational.

Table of Contents

CHAPTER 1: WARNING LABELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
CHAPTER 2: GENERAL SAFETY RECOMMENDATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
CHAPTER 3: SCOPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SECTION 3.1: To the Customer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SECTION 3.2: Objective . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
CHAPTER 4: GETTING STARTED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SECTION 4.3: Safety Standard Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SECTION 4.4: Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SECTION 4.5: Information Provided by Door Supplier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
CHAPTER 5: GENERAL SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
CHAPTER 6: OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
CHAPTER 7: FULL AUTOMATIC SWING DOOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SECTION 7.1: Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SECTION 7.2: Sensor Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SECTION 7.3: Sensor Malfunctions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SECTION 7.4: Daily Safety Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SECTION 7.5: Safety Decals for Full Automatic Swing Doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
CHAPTER 8: LOW ENERGY SWING DOOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Section 8.6: Daily Safety Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Section 8.7: Safety Decals for Low Energy Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
NABCO hours of Operation: Monday to Friday 8:00 a.m.- 4:30 p.m. (Central Time)
Model GT20
OWNER'S MANUAL
A Founding Member of: AAADM
WARNING
S82 W18717 Gemini Drive; Muskego, Wisconsin 53150
Technical Support: (866) 622-8325
Phone: (877) 622-2694
Fax: (888) 679-3319
www.nabcoentrances.com
Part #C-00170
Rev. 8/29/17

Advertisement

Table of Contents
loading

Summary of Contents for Nabco GT20

  • Page 1: Table Of Contents

    • Turn OFF all power to the Automatic Door if a Safety System is not working. • Instruct the Owner to keep all power turned OFF until corrective action can be achieved by a NABCO trained technician. Failure to follow these practices may result in serious consequences.
  • Page 2: Chapter 1: Warning Labels

    GT20 Swing Door Owners Manual www.NabcoEntrances.com Part #C-00170 Rev. 8-29-17 Please refer to this section in the event a warning label within this manual needs further explanation. CHAPTER 1: WARNING LABELS Indicates a hazardous situation which has some probability of severe injury. It should not be considered for WARNING property damage unless personal injury risk is present.
  • Page 3: Section 4.3: Safety Standard Compliance

    In the United States, ANSI Standard 156.10 (Used to cover Full Automatic doors) applies, and ANSI Standard 156.19 (Used to cover Low Energy doors) applies. NABCO Entrances Inc., for its Gyro-Tech product line, provides to its purchasing distributor a limited warranty on the equipment SECTION 4.4: Limited Warranty supplied by NABCO Entrances Inc.
  • Page 4: Chapter 6: Operation

    GT20 Swing Door Owners Manual www.NabcoEntrances.com Part #C-00170 Rev. 8-29-17 CHAPTER 6: OPERATION Power Mode Bu on Automa c Switch Night Hold Open Manual Exit Mode Bu on DN 1722 Power Switch When the switch is in the ON postion, all activation signals are accepted and the door is...
  • Page 5: Section 7.3: Sensor Malfunctions

    Presence Sensors detect both moving and non-moving objects in the path of the door and signal the Control Unit accordingly.  7.2.2 Presence Sensor NABCO Entrances utilizes infrared technology in its presence sensors. Motion/Presence Sensors provide motion detection, and pedestrain safety.  7.2.3 Motion/Presence Sensor Table 1 Some (not all) Common cause examples for Sensor Malfunctions...
  • Page 6: Section 7.4: Daily Safety Check

    GT20 Swing Door Owners Manual www.NabcoEntrances.com Part #C-00170 Rev. 8-29-17 Multiple Sensors installed close to each other, or facing each other Within 197” (5m) DN 1569 SECTION 7.4: Daily Safety Check If the Swing Door will not be used for at least (1) month, it is recommended to turn Power OFF to the Unit.
  • Page 7 GT20 Swing Door Owners Manual Rev. 8-29-17 Part #C-00170 4. Walk out of the Activating Zone. a. After a brief time delay (at least 1-1/2 seconds), the door should fully close smoothly, without impact. b. If two-way traffic, move toward swing side of door. Door should open well before the swing path is reached.
  • Page 8: Section 7.5: Safety Decals For Full Automatic Swing Doors

    GT20 Swing Door Owners Manual www.NabcoEntrances.com Part #C-00170 Rev. 8-29-17  7.4.4 Mat Activation Check for Activating Side of Swing Door Minimum Required Exposed Length Ac va ng Door Pivot Threshold Swing Door Safety Minimum Required Guide Rail Exposed Length Minimum length to end of door in open posi on Figure 3 Activate Floor Mat...
  • Page 9: Chapter 8: Low Energy Swing Door

    GT20 Swing Door Owners Manual Rev. 8-29-17 Part #C-00170 DO NOT Enter (side one) Directional Signs used to define Traffic Flow. Decal Description X  Directional Arrow (side two) Adhere to swing door panel. X  Must be visible from both sides.
  • Page 10: Section 8.7: Safety Decals For Low Energy Units

    GT20 Swing Door Owners Manual www.NabcoEntrances.com Part #C-00170 Rev. 8-29-17 Doors shall be equipped with (a) decal(s) visible from either side, instructing the user as to the operation and function of the Section 8.7: Safety Decals for Low Energy Units door. The decal shall be mounted 50 inches, +/- 12 inches, from the floor to the centerline of the decal. The letters shall be 5/8 inch high minimum.

Table of Contents