• Turn OFF all power to the Automatic Door if a Safety System is not working.
WARNING
• Instruct the Owner to keep all power turned OFF until corrective action can be achieved
• NEVER leave a Door operating without all Safety detection systems operational.

Table of Contents

CHAPTER 1: SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
CHAPTER 2: SCOPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SECTION 2.1: To the Installer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SECTION 2.2: Objective . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SECTION 2.4: QR Code Links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
CHAPTER 3: GETTING STARTED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SECTION 3.1: Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SECTION 3.2: Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SECTION 3.3: General Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SECTION 3.4: Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SECTION 3.5: Output Power Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SECTION 3.7: Navigate with the Rotary Dial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
SECTION 3.6: The Opus Control for Swing Doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SECTION 3.8: IO Terminal strips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
SECTION 3.9: Relay Output Terminal Strip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
SECTION 3.10: CAN Bus Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
CHAPTER 4: LCD CATEGORY SCREENS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
SECTION 4.1 Level One: Specification Screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
SECTION 4.2 Level Two: Access Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
SECTION 4.3 Enter Passcode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
SECTION 4.4 Cancel Passcode or Reset to Default . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
SECTION 4.5 Level Three and Four: Setting Category and Menu Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
CHAPTER 5: STROKE LEARNING (SWING AND FOLD DOORS) . . . . . . . . . . . . . . . . . . . . . . . . . . 9
SECTION 5.1 Stroke Learning (YES) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
SECTION 5.2 Error Message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
SECTION 6.1: Copy Data from Type 2 (Master Control) to Type 1 (Slave Control) . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
SECTION 6.2: Resetting a Type 2 Control back to a Type 1 Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
SECTION 6.3: Customized Programming/Settings for (1) Control only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
NABCO Entrances Inc. S82 W18717 Gemini Drive Muskego, Wisconsin 53150
Phone: (877) 622-2694 Fax: (888) 679-3319 www.nabcoentrances.com
NABCO hours of Operation: Monday to Friday 8:00 a.m.- 4:30 p.m. (Central Time)
by a NABCO trained technician. Failure to follow these practices may result in serious
consequences.
Swing Door and Fold Door Opus Control
Wiring and Programming
Installation Manual
P/N C-00139 Rev 8-11-21
1 of 32

Advertisement

Table of Contents
loading

Summary of Contents for Nabco C-00139

  • Page 1: Table Of Contents

    WARNING • Instruct the Owner to keep all power turned OFF until corrective action can be achieved by a NABCO trained technician. Failure to follow these practices may result in serious consequences. • NEVER leave a Door operating without all Safety detection systems operational.
  • Page 2 Swing and Fold Door Opus Control Wiring and Programming Installation Manual www.NabcoEntrances.com P/N C-00139 Rev 8-11-21 CHAPTER 7: SENSORS WITH MONITORING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 CHAPTER 8: PROGRAMMING MENUS .
  • Page 3: Chapter 1: Safety

    SwingandFoldDoorOpusControlWiringandProgrammingInstallationManual Rev. 8-11-21 P/N C-00139 CHAPTER 1: SAFETY SECTION 1.1: Warning Labels Warning labels are universal and used to alert an individual of potential harm to one’s self or to others. The following warning labels are listed in a hierarchy order that defines the most potential danger first, and the least potential danger last.
  • Page 4: Chapter 2: Scope

    Use them in addition to the ANSI standards. If after troubleshooting a problem, a satisfactory solution cannot be achieved, please call Nabco Entrances at 1-877-622-2694 between 8 am – 4:30 pm Central time for additional assistance. This manual offers step by step instructions. Do Not take shortcuts.
  • Page 5: Chapter 3: Getting Started

    Note: All Wiring Diagrams included within this manual, reflect typical primary and secondary circuits that might be commonly used. On site wiring may be different from that shown. Note: NABCO factory utilizes Underwriters Laboratories (UL) recognized component wire, terminals and connector housings to Table 1 Power Draw Common Accessories manufacture all Automatic Door systems.
  • Page 6: Section 3.5: Output Power Guidelines

    Modules Accessories Auxiliary Equipment An auxiliary power supply, (e.g. NABCO Transformer 24VDC power supply p/n V-00022) must be utilized if TOTAL current draw exceeds 0.7A. The Opus Control must Not be used to power: Magnetic Locks nor Electric Locks CAUTION To determine if an auxiliary power supply must be used, add the total current draw of all devices.
  • Page 7: Section 3.8: Io Terminal Strips

    SwingandFoldDoorOpusControlWiringandProgrammingInstallationManual Rev. 8-11-21 P/N C-00139   • Clockwise: To scroll forward through screens and programming options . Turn the Rotary Dial (2) clicks to advance through each menu item: • Counterclockwise: To scroll backward through screens and programming options . SECTION 3.8: IO Terminal strips...
  • Page 8: Section 4.1 Level One: Specification Screens

    Swing and Fold Door Opus Control Wiring and Programming Installation Manual www.NabcoEntrances.com P/N C-00139 Rev 8-11-21 SECTION 4.1 Level One: Specification Screens ANSI SPECS TERMINAL SPECS UNIT SPECS ERROR SPECS Terminal ANSI specs (reference) Type: GT710 Swing Error Screen 1 12VDC Status:...
  • Page 9: Section 4.3 Enter Passcode

    SwingandFoldDoorOpusControlWiringandProgrammingInstallationManual Rev. 8-11-21 P/N C-00139 Attention:  Do Not activate Passcode (0045) until programming of the Opus Control is complete. Failure to do so, will force the User to enter (0045) each time a change is made. SECTION 4.3 Enter Passcode LEVEL 2...
  • Page 10: Section 5.1 Stroke Learning (Yes)

    Note: Simultaneous Pair settings apply to any Simultaneous Pair, or Double Egress having (2) Operators. Note: Units are setup to operate as a pair at the NABCO Factory and shipped accordingly. Note: For Headers with stacked Opus Controls, the Type 2 Control is always installed on top of the Type 1 Control.
  • Page 11: Section 6.1: Copy Data From Type 2 (Master Control) To Type 1 (Slave Control)

    SwingandFoldDoorOpusControlWiringandProgrammingInstallationManual Rev. 8-11-21 P/N C-00139 SECTION 6.1: Copy Data from Type 2 (Master Control) to Type 1 (Slave Control) 1. Go to the Type 2 (Master Control). 2. Push the Rotary Dial in for 2 seconds, release. 3. Push the Rotary Dial in again 2 seconds for (Copy Data (YES or NO).
  • Page 12: Section 6.3: Customized Programming/Settings For (1) Control Only

    Swing and Fold Door Opus Control Wiring and Programming Installation Manual www.NabcoEntrances.com P/N C-00139 Rev 8-11-21 SECTION 6.3: Customized Programming/Settings for (1) Control only Note:  Customized Programming/Settings can be done for (1) Control without losing data previously saved for (2) Controls. Sometimes Programming/Settings need to change for (1) Control only. For example, Door (1) needs to open faster than Door (2).
  • Page 13: Section 8.2: Movement Settings

    SwingandFoldDoorOpusControlWiringandProgrammingInstallationManual Rev. 8-11-21 P/N C-00139 Base Setting Setting Category Menu Item Default Action ► Left Door Hand   Left From the Exterior Side of Building, determine which Handing to (for Fold Doors) ► Right   enter: Left or Right...
  • Page 14 Swing and Fold Door Opus Control Wiring and Programming Installation Manual www.NabcoEntrances.com P/N C-00139 Rev 8-11-21 Optional Setting Parameter Range Default Description Manual Open Function Open Assist No Action ► Assisted Power from motor when door is pushed   ► Assisted Power depends on how strong door is pushed  ...
  • Page 15: Section 8.4: Output Settings

    SwingandFoldDoorOpusControlWiringandProgrammingInstallationManual Rev. 8-11-21 P/N C-00139 Optional Setting Parameter Range Default Description Open fi rst, Latch check is wide Opus Se ngs Overlap Sim Pair Normal Sim Pair Connec on Ac va on No Ac va on DN 1558 Flip Screen Choose Yes if Opus is installed upside down.
  • Page 16: Section 8.5: Input Settings

    Swing and Fold Door Opus Control Wiring and Programming Installation Manual www.NabcoEntrances.com P/N C-00139 Rev 8-11-21 SECTION 8.5: Input Settings Input Setting Parameter Terminal Default Range Description Input 62 Setting Terminal 4 Ext Activation ► — —   ► No input  ...
  • Page 17: Section 8.6: History Setting

    SwingandFoldDoorOpusControlWiringandProgrammingInstallationManual Rev. 8-11-21 P/N C-00139 Input Setting Parameter Terminal Default Range Description After 6B Open? ► Yes   Determines door movement open or close, Not Active after 6B. ► No   ► Active 61 Monitoring   Sensor monitoring function * Not Active ►...
  • Page 18: Chapter 9: Common Program Adjustments

    Swing and Fold Door Opus Control Wiring and Programming Installation Manual www.NabcoEntrances.com P/N C-00139 Rev 8-11-21 CHAPTER 9: COMMON PROGRAM ADJUSTMENTS SECTION 9.1: Recycle Count “Reset” LEVEL 2 LEVEL 1 LEVEL 3 Passcode Push and Hold 1. Rotate Dial to select UNIT SPECS Go to Se ng menu Se ng Category Rotary Dial (2 Sec.)
  • Page 19: Chapter 10: Shut Off Circuit Breaker

    Attention:  Insert all Incoming 120 VAC Power wires into the pre drilled Electric Service Access Hole located at the left or right side of Header End Cap. Attention:  Electrical circuit to Nabco operator must not be not shared with other equipment such as lighting, cash registers, or any device that might cause electrical interference on the circuit.
  • Page 20: Section 11.2: Motor Wiring

    Swing and Fold Door Opus Control Wiring and Programming Installation Manual www.NabcoEntrances.com P/N C-00139 Rev 8-11-21 SECTION 11.2: Motor Wiring  11.2.1 GT8300/8400/8500 ENCODER MOTOR WIRING NON ENCODER WIRING Brake Module To Door Handing Harness Motor Non-Encoder Posi on Switches (Right Hand Units) Harness...
  • Page 21: Section 11.4: Activation

    SwingandFoldDoorOpusControlWiringandProgrammingInstallationManual Rev. 8-11-21 P/N C-00139 SECTION 11.4: Activation 2 3 4 5 6 7 9 10 1 2 3 4 5 6 7 9 10 21 of 32...
  • Page 22: Section 11.5: Activation Using On/Off/Hold-Open Switch

    Swing and Fold Door Opus Control Wiring and Programming Installation Manual www.NabcoEntrances.com P/N C-00139 Rev 8-11-21 SECTION 11.5: Activation using ON/OFF/Hold-Open Switch NOTE: Rocker Switch If not using the Rocker Switch, change P.N. A-00805 "INPUT BA CIRCUIT" to "NORMALLY OPEN" Hold Open...
  • Page 23: Section 11.6: Safety Without Monitoring

    SwingandFoldDoorOpusControlWiringandProgrammingInstallationManual Rev. 8-11-21 P/N C-00139 SECTION 11.6: Safety without Monitoring 1 2 3 4 5 6 7 9 10 23 of 32...
  • Page 24: Section 11.7: Safety With Monitoring

    Swing and Fold Door Opus Control Wiring and Programming Installation Manual www.NabcoEntrances.com P/N C-00139 Rev 8-11-21 SECTION 11.7: Safety with Monitoring 2 3 4 9 10 1 2 3 4 8 9 10 11 13 14 1 2 3 4 24 of 32...
  • Page 25: Section 11.8: Lock

    SwingandFoldDoorOpusControlWiringandProgrammingInstallationManual Rev. 8-11-21 P/N C-00139 SECTION 11.8: Lock 25 of 32...
  • Page 26: Section 11.9: Single Full Automatic With Monitoring

    Swing and Fold Door Opus Control Wiring and Programming Installation Manual www.NabcoEntrances.com P/N C-00139 Rev 8-11-21 SECTION 11.9: Single Full Automatic with Monitoring 2 3 4 9 10 11 13 13 14 8 9 10 11 1 2 3 4 26 of 32...
  • Page 27: Section 11.10: Simultaneous Pair Full Automatic With Monitoring

    SwingandFoldDoorOpusControlWiringandProgrammingInstallationManual Rev. 8-11-21 P/N C-00139 SECTION 11.10: Simultaneous Pair Full Automatic with Monitoring Rocker Switch P.N. A-00805 Hold Open BLUE BLACK WHITE Ac va on Sensor PWR+ PWR– N.O. Door Mounted Approach Side Sensor Opus Sim-Pair Harness PWR+ PWR– N.O. TEST+ TEST–...
  • Page 28: Section 11.11: Connecting A Break-Out Switch

    Swing and Fold Door Opus Control Wiring and Programming Installation Manual www.NabcoEntrances.com P/N C-00139 Rev 8-11-21 SECTION 11.11: Connecting a Break-Out Switch BREAK OUT WITH ON/OFF/HOLD OPEN SWITCH ON/OFF/Hold-Open Switch P/N A-00805 Break-out Switch wired in series with Blue Wire from ON/OFF/Hold-Open Switch...
  • Page 29: Section 11.12: No Security System: One Way / Two Way Operation

    SwingandFoldDoorOpusControlWiringandProgrammingInstallationManual Rev. 8-11-21 P/N C-00139 SECTION 11.12: No Security System: One Way / Two Way Operation Rocker Switch Exterior Push-Plate Interior Push-Plate P.N. A-00805 Hold Open BLACK WHITE BLUE N.O. N.O. N.O. DRY CONTACT EXTERIOR SECURE N.C. ACCESS DEVISE CARD READER KEYPAD ETC.
  • Page 30: Chapter 12: Fold Door Wiring Diagram

    Swing and Fold Door Opus Control Wiring and Programming Installation Manual www.NabcoEntrances.com P/N C-00139 Rev 8-11-21 CHAPTER 12: FOLD DOOR WIRING DIAGRAM Attention:  DO NOT copy data from a Type 1 control. If data is copied from a Type 1 control: ► The Type 1 control will change itself to a Type 2 control.
  • Page 31: Chapter 13: Troubleshooting

    P/N C-00139 CHAPTER 13: TROUBLESHOOTING Notice: If after troubleshooting a problem, and a satisfactory solution cannot be achieved, please call Nabco Entrances at 1-877-622-2694 between 8 am – 4:30pm Central time for additional assistance. DO NOT leave any problem unresolved. If the door cannot be repaired immediately, turn off the door and leave it inoperable until repairs can be made.
  • Page 32 Swing and Fold Door Opus Control Wiring and Programming Installation Manual www.NabcoEntrances.com P/N C-00139 Rev 8-11-21 Error Messages Drive-Motor error Opus Error Msg NET-HT Error Msg Resolution Drive-A/D error Drive ► Check all connections between the Control and Motor.  ...