Teledyne 4700 Installation And Operation Manual page 66

Refrigerated samplers
Hide thumbs Also See for 4700:
Table of Contents

Advertisement

Isco 4700 Refrigerated Sampler
Section 4 Operation
COLLECTED
___ OF ___ SAMPLES
MISSED SAMPLES: ___
(error message)
PROGRAM STARTED
HH:MM
DD-MON-YY
PROGRAM COMPLETED
HH:MM
DD-MON-YY
PROGRAM HALTED
HH:MM
DD-MON-YY
PROGRAM PAUSED
___ SAMPLES REMAIN
POWER LOST
HH:MM
DD-MON-YY
REFRIG TEMP DATA:
AVERAGE: __ C
LAST CALIBRATED
HH:MM
DD-MON-YY
LAST PROGRAMMED
HH:MM
DD-MON-YY
CLOCK SET AT
HH:MM
DD-MON-YY
4700 SAMPLER
ID: ___________
HARDWARE: ___
SOFTWARE: _._
TEXT TRANSLATION
REVISION: __
WARNING:
CHANGE PUMP TUBE
4-4
The log generally contains the following information:
1. The log reports the number of successful samples out of the
total number programmed.
2. If samples were not collected, the log reports the number of
missed samples and the error message. If there are multi-
ple reasons, this screen will be repeated for the other error
messages. Error messages are described in Table 4-1.
3. The log reports the time and date the program was started.
4. If the program was allowed to finish, the log reports the
time and date the program was completed.
5. If the program was halted before the programmed comple-
tion time, the log reports the time.
6. If you are viewing the log while the program is paused, the
log displays the number of samples that remain.
7. If power was lost during the program, the log reports the
time of the most recent power failure event and the time
that power was restored.
8. The log reports the average refrigerator temperature and
the most recent time of the minimum and maximum
recorded temperatures.
9. The log reports the time and date of the last sample vol-
ume calibration (see section 4.5), or the last DEFINE SAM-
PLE (see example "Defining the Sample Volume" on page
3-21).
10. The log reports the last time the program was modified.
11. The log reports the last time the clock was set.
12. The log reports the unique ID for the sampler control
panel. This identifier is assigned at the factory.
13. The log reports the hardware and software revision of the
control panel.
14. If the sampler displays a language other than English, the
translation revision is displayed.
15. If the pump tubing count is exceeded the log will display a
warning. For more information on the pump tube warning
see sections 3.3.9 and 5.1.2.