7. Using the terminal opener provided, connect cores (except coaxial cable) to their appropriate
locations on TB801 on the PCB 03P9436. Refer to the interconnection diagram for wiring
details.
Wire
Twist.
TB802 on
PCB 03P9435
Cable gland for
HV cable (TPYCY-1.5)
Cable gland for
power cable (TPYCY-2.5)
Fix coax cable with
with this clamp.
2-4
Push down.
Terminal
opener
WAGO connector
How to wire WAGO connector
Fasten shield of signal cable here.
Antenna unit, front view
Procedure
1. Twist core.
2. Insert terminal opener as shown and push down.
3. Insert core into hole.
4. Release terminal opener.
5. Tug on wire to confirm that it is firmly in place.
Terminal TB901