Furuno NAVNET 1734C Operator's Manual page 61

Marine radar; color video plotter
Hide thumbs Also See for NAVNET 1734C:
Table of Contents

Advertisement

2. RADAR OPERATION
2. Press the TARGET soft key.
3. Place the cursor on the target to acquire.
4. Press the ACQ soft key.
5. Press the RETURN soft key to finish.
The plot symbol changes over time as below. A vector appears about one minute after
acquisition, indicating the target's motion trend.
* = Target number shown when TARGET ID NUMBER is
turned on in the ARP SETUP menu.
Note: In case of the acquisition by an external ARP, the acquisition circle mark appears one
minute after acquisition.
Automatic acquisition
The ARP can acquire up to ten targets
automatically by setting an automatic
acquisition area. When automatic acquisition is
selected after acquiring targets manually, only
the remaining capacity for targets may be
automatically acquired. For example, if seven
targets have been manually acquired, three
targets may be automatically acquired.
1. Press the MENU key to show the main
menu.
2. Press the ARP SETUP soft key to show the ARP SETUP menu.
3. Operate the Cursor pad to select AUTO ACQUISITION AREA.
4. Press the EDIT soft key to show the automatic acquisition area window.
AUTO ACQ. AREA
¡
ON
¤
OFF
Automatic acquisition area window
5. Select ON, then press the ENTER soft key.
6. Press the MENU key to close the menu. An acquisition area of 2.0 to 2.5 miles in range
and ±45º on either side of the heading line in bearing appears.
Note: Targets being tracked in automatic acquisition are continuously tracked when
switching to manual acquisition.
2-30
ARP plot symbols
45 port
45 starboard
Automatic acquisition area

Hide quick links:

Advertisement

Table of Contents