Installation - Graco 226816 Instructions-Parts List Manual

Viscon high pressure fluid heater
Hide thumbs Also See for 226816:
Table of Contents

Advertisement

Grounding
WARNING
FIRE AND EXPLOSION HAZARD
Before operating the pump, ground the
system as explained below. Also read
the section FIRE AND EXPLOSION
HAZARD on page 4.
1. Pump: use a ground wire and clamp as shown in
your separate pump manual.
2. Air hoses: use only electrically conductive air
hoses.
3. Fluid hoses: use only electrically conductive fluid
hoses.
4. Heater: by wiring to a properly grounded power
supply through the electrical connections. In a
mobile installation, be sure the truck or trailer is
grounded to a true earth ground, also.

Installation

5. Air compressor or hydraulic power supply: follow
manufacturer's recommendations.
6. Spray gun: grounding is obtained through connec-
tion to a properly grounded fluid hose and pump.
7. Object being sprayed: according to your local
code.
8. All solvent pails used when flushing, according to
local code. Use only metal pails, which are con-
ductive, placed on a grounded surface. Do not
place the pail on a nonconductive surface, such as
paper or cardboard, which interrupts the grounding
continuity.
9. To maintain grounding continuity when flushing or
relieving pressure, always hold a metal part of the
gun firmly to the side of a grounded metal pail,
then trigger the gun.
307363
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

226819

Table of Contents