Technical Data - Graco 226816 Instructions-Parts List Manual

Viscon high pressure fluid heater
Hide thumbs Also See for 226816:
Table of Contents

Advertisement

Category
Voltage
Explosion proof
Heating element wattage
Fluid passage area
Fluid passage diameter and length
Working pressure
Thermometer range
Temperature range
Weight
* This heater has a surface temperature code (identification code) of T3C, indicating a maximum external (surface)
temperature rating of 160_C (320_F) in accordance with Article 500 – Hazardous Locations – of NFPA 70 National
Electrical Code and/or Section 18 – Hazardous Locations – of Part 1 of the Canadian Electrical Code. See and
comply with the requirements of these and similar codes as to the proper location of the heater.
20
307363

Technical Data

Data
Model 226816, Series F: 120 volts AC, single phase, 18 amp
Model 226819, Series F: 240 volts AC, single phase, 9 amp
Class 1 – Division 1 & 2, Group D, Hazardous Location
2100 watts
254 sq. in. (163, 870 mm
2
.013 watts/mm
0.56 in. (14.2 mm
up to 3000 psi (21 MPa, 207 bar) maximum
0 to 250_F (–18 to 121_C)
80 to 190_F (26 to 88_C)
37.5 lb (17 kg)
2
)—8 watts per sq. in.;
) of heat transfer area
2
), 12 ft (3.7 m)

Advertisement

Table of Contents
loading

This manual is also suitable for:

226819

Table of Contents