Frymaster SM20 Installation & Operation Manual page 26

Super marathon series gas fryers
Table of Contents

Advertisement

3.7 Gas Conversion Procedures (cont.)
NON-CE UNITS ONLY:
See gas valve illustration below and gas valve, burner and orifice location on page 3-15 when
performing the following conversions.
When converting from natural gas to propane (or vice-versa), the following procedures apply:
♦ Burner orifices and pilot orifice MUST be replaced (see page 3-11 for required component
part numbers).
♦ Adjust orifice gas pressure by turning the gas-valve adjustment screw (see page 3-11 for gas
types and pressures).
♦ After adjustment, replace the adjustment-screw cover.
♦ Affix the new label included with the conversion kit next to the existing rating plate stating
that the gas type has been converted. Remove any references to the previously used gas
from the existing rating plate.
Conversion from one gas family to another (i.e. changing from natural gas to propane) requires
special components. Obtain the necessary components using the tables on page 3-11.
Conversions can only be executed by qualified, factory-authorized personnel.
ON/PILOT/OFF
Gas-Cock Knob
Pilot pressure adjustment
(remove cover screw to access)
SUPER MARATHON SERIES GAS FRYERS
CHAPTER 3: INSTALLATION INSTRUCTIONS
Typical gas valve (Millivolt- Non-CE).
Pressure flow adjustment
(remove cover screw to access)
Regulator Vent
Pilot gas supply connection
Pressure Tap
3-14

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sm40Sm50Sm60Sm80Non-ce & super marathon seriesSm20 series ... Show all

Table of Contents