Bosch DIVAR IP all-in-one 7000 3U Quick Installation Manual page 13

Hide thumbs Also See for DIVAR IP all-in-one 7000 3U:
Table of Contents

Advertisement

DIVAR IP all-in-one 7000 3U
11
Control panel buttons
Control panel LEDs
The control panel LEDs provide status information about the system.
Power failure
Information
Bosch Security Systems B.V.
3
IPMI LAN
5
USB port 3.1 Gen 2 (Type C)
7
VGA display output (disabled)
9
2 Display ports
Audio MIC in
Button
Description
The power button is used to apply or remove power from the power supply to
the system.
Note: Turning off system power with this button removes the main power,
Power
but keeps standby power supplied to the system.
To remove all power, unplug the system before performing maintenance
tasks.
The reset button is used to reboot the system.
Reset
LED
Description
This LED indicates that a power supply module has failed.
This LED indicates the system status.
System status
Continuously on and red
Blinking red (1 Hz)
Blinking red (0.25 Hz)
Solid blue
Blinking blue (300 msec)
4
6
8
10
Description
An overheat condition has occurred. (This
may be caused by cable congestion.)
Fan failure: check for an inoperative fan.
Power failure: check for an inoperative
power supply.
Local UID has been activated. Use this
function to locate the unit in a rack
environment.
Remote UID has been activated. Use this
function to locate the unit from a remote
location.
Quick installation guide
System overview | en
3 USB ports 3.1 Gen 2 (Type A)
2 LAN ports (teamed)
Note: Do not change the teaming
mode!
DVI-I port
Audio Line out
13
2021.10 | V02 | DOC

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dip-73g0-00nDip-73g8-16hdDip-73gc-16hd

Table of Contents