TABLE
COMPRESR (cont)
COMPTRIP
DMANDLIM
ECON_MIN
APPENDIX B — CCN TABLES (cont)
MAINTENANCE DISPLAY TABLES (cont)
DISPLAY NAME
Enable Compressor B1
Compressor B2 Relay
Compressor B2 Feedback
Curr.Sens.Brd. B2 Status
CSB B2 Feedback Alarm
Comp B2 Locked Out ?
Compressor B2 Strikes
Enable Compressor B2
Comp. Security Password
Low SP Circ.A Trip 48.0
Low SP Circ.B Trip 48.0
MOP 1/3 Lo SP Trip 28.0
MOP 1/3 Lo DP Trip 242.7
MOP 1/3 Hi SP Trip 75.0
MOP 1/3 Hi DP Trip 430.0
MOP 1/3 Mm DP Trip 3.985
MOP 1/3 Mb DP Tr 131.117
MOP 1/2 Lo SP Trip 28.0
MOP 1/2 Lo DP Trip 242.7
MOP 1/2 Hi SP Trip 61.5
MOP 1/2 Hi DP Trip 430.0
MOP 1/2 Mm DP Trip 5.591
MOP 1/2 Mb DP Trp 156.55
MOP 2/3 Lo SP Trip 28.0
MOP 2/3 Lo DP Trip 316.2
MOP 2/3 Hi SP Trip 57.4
MOP 2/3 Hi DP Trip 430.0
MOP 2/3 Mm DP Trip 3.871
MOP 2/3 Mb DP Trp 207.82
MOP Ful Lo SP Trip 28.0
MOP Ful Lo DP Trip 340.0
MOP Ful Hi SP Trip 52.4
MOP Ful Hi DP Trip 430.0
MOP Ful Mm DP Trip 3.689
MOP Ful Mb DP Trp 103.28
Active Demand Limit
Percent Total Capacity
Demand Limit Select
Demand Limit Switch 1
Demand Limit Switch 2
Demand Limit Sw.1 Setpt.
Demand Limit Sw.2 Setpt.
4-20 ma Demand Signal
Demand Limit at 20 ma
CCN Loadshed Signal
Loadshed Group Number
Loadshed Demand Delta
Maximum Loadshed Time
Economizer Act.Cmd.Pos.
Economizer Act.Curr.Pos.
Economzr 2 Act.Curr.Pos.
Econo Current Min. Pos.
Econo Current Min. CFM
Outside Air CFM
Diff.Air Quality in PPM
IAQ Min.Pos.Override
Econ Remote 10K Pot Val.
IAQ - PPM Return CO2
OAQ - PPM Return CO2
IAQ - Discrete Input
IAQ Demand Vent Min.Pos.
Economizer Min.Position
IAQ Demand Vent Min.Flow
Economizer Min.Flow
Econ OACFM MinPos Deadbd
IAQ Analog Sensor Config
IAQ 4-20 ma Fan Config
IAQ Discrete Input Confg
IAQ Disc.In. Fan Config
IAQ Econo Override Pos.
Diff.Air Quality LoLimit
Diff.Air Quality HiLimit
DAQ PPM Fan Off Setpoint
DAQ PPM Fan On Setpoint
Diff. AQ Responsiveness
IAQ Low Reference
IAQ High Reference
OAQ Lockout Value
OAQ 4-20ma Sensor Config
IAQ milliamps
OAQ milliamps
RANGE
UNITS
Enable/Disable
On/Off
On/Off
ascii
Enable/Disable
Yes/No
Enable/Disable
0-10000
PSIG
PSIG
PSIG
PSIG
PSIG
PSIG
PSIG
PSIG
PSIG
PSIG
PSIG
PSIG
PSIG
PSIG
PSIG
PSIG
0-100
%
0-100
%
0-3
On/Off
On/Off
0-100
%
0-100
%
4-20
ma
0-100
%
0-99
0-99
0-60
%
0-120
min
%
%
%
%
CFM
CFM
%
%
%
CFM
CFM
CFM
%
ma
ma
151
POINT NAME
WRITE STATUS
CMPB1ENA
config
CMPB2
CSB_B2
CSBB2ASC
CSB_B2EN
config
CMPB2LOK
CMPB2STR
CMPB2ENA
config
COMPPASS
config
LSPATRIP
config
LSPBTRIP
config
SP13L_T
config
DP13L_T
config
SP13H_T
config
DP13H_T
config
DP13Mm_T
config
DP13Mb_T
config
SP12L_T
config
DP12L_T
config
SP12H_T
config
DP12H_T
config
DP12Mm_T
config
DP12Mb_T
config
SP23L_T
config
DP23L_T
config
SP23H_T
config
DP23H_T
config
DP23Mm_T
config
DP23Mb_T
config
SPFLL_T
config
DPFLL_T
config
SPFLH_T
config
DPFLH_T
config
DPFLMm_T
config
DPFLMb_T
config
DEM_LIM
forcible
CAPTOTAL
DMD_CTRL
config
DMD_SW1
forcible
DMD_SW2
forcible
DLSWSP1
config
DLSWSP2
config
DMDLMTMA
forcible
DMT20MA
config
DL_STAT
SHED_NUM
config
SHED_DEL
config
SHED_TIM
config
ECONOCMD
forcible
ECONOPOS
ECON2POS
ECMINPOS
ECMINCFM
OACFM
DAQ
IAQMINOV
forcible
ECON_POT
forcible
IAQ
forcible
OAQ
forcible
IAQIN
forcible
IAQMINP
config
ECONOMIN
config
OACFMMIN
config
OACFMMAX
config
OACFM_DB
config
IAQANCFG
config
IAQANFAN
config
IAQINCFG
config
IAQINFAN
config
IAQOVPOS
config
DAQ_LOW
config
DAQ_HIGH
config
DAQFNOFF
config
DAQFNON
config
IAQREACT
config
IAQREFL
config
IAQREFH
config
OAQLOCK
config
OAQANCFG
config
IAQ_MA
OAQ_MA