ACCSY —
Accessory
ACC'Y
Accessory
AF
Airfoil
AN
Analog
APS
Air Pressure Switch
BM
Blower Motor
BR
Blower Relay
C
Compressor Contactor
CB
Compressor Circuit Breaker
CBT
Circuit Breaker, Transformer
CCB
Control Circuit Breaker
CCN
Carrier Comfort Network®
CCT
Cooling Coil Thermistor
CEM
Controls Expansion Module
CH
Crankcase Heater
CM
Combustion Motor
COMP
Compressor
CR
Control Relay
CSB
Current Sensor Board
CV
Constant Volume
DI
Digital Input
DPT
Discharge Pressure Transducer
ECB
Economizer Control Board
ECON
Economizer
EQUIP
Equipment
FU
Fuse
GND
Ground
GVR
Gas Valve Relay
HC
Heater Contactor
HIR
Heat Interlock Relay
HPS
High-Pressure Switch
HS
Hall Effect Sensor
HV
High Voltage
I
Ignitor
RED LED - STATUS
J1
J2
J3
J4
J5
J6
J7
ROOFTOP CONTROL BOARD (RCB) — The RCB has
additional inputs and outputs required for the control of the
unit. All units have an RCB board. See Fig. 27. The board has
9 inputs and 8 outputs. Details can be found in Table 88. The
RCB board is located in the main control box.
ECONOMIZER CONTROL BOARD (ECB) — The ECB
is used on size 075-105 units with high-capacity power exhaust
or return/exhaust fan. See Fig. 27. The ECB board sends a 4 to
20 mA signal to the VFD to control the exhaust fan speed. The
board also has inputs to sense the return fan cfm and supply fan
LEGEND FOR FIG. 15-25
IAQ
IDM
IFC
IFCB
IFM
IGC
IGV
IP
LEI
LEN
LS
MBB
MGV
MMC
MMR
MOD PE —
NEC
OA
OAQ
OAT
OD
OFC
OFM
OPT
PE
PEC
PECB
PEM
PL
PTC
RA
RAT
RCB
GREEN LED - LEN (LOCAL EQUIPMENT NETWORK)
CEPL130346-01 HK 50AA029 CE BO 430346
STATUS
LEN
Fig. 26 — Main Base Board (MBB)
Indoor Air Quality
Induced Draft Motor
Indoor Fan Contactor
Indoor Fan Circuit Breaker
Indoor Fan Motor
Integrated Gas Controller
Inlet Guide Vane
Internal Protector
Local Equipment Interface
Local Equipment Network
Limit Switch
Main Base Board
Main Gas Valve
Motormaster® Contactor
Motormaster Relay
Modulating Power Exhaust
National Electrical Code
Outdoor Air
Outdoor Air Quality
Outdoor-Air Thermostat
Outdoor
Outdoor Fan Contactor
Outdoor Fan Motor
Option
Power Exhaust
Power Exhaust Contactor
Power Exhaust Circuit Breaker
Power Exhaust Motor
Plug Assembly
Positive Temperature Coefficient
Power Reference
Return Air
Return Air Thermistor
Rooftop Control Board
YELLOW LED -
CCN (CARRIER COMFORT NETWORK)
J8
cfm. This board is located in the main control box. Input and
output assignments are summarized in Table 89.
STAGED GAS HEAT BOARD (SCB) — When optional
staged gas heat is used, the SCB board is installed and controls
additional stages of gas heat. See Fig. 28. The SCB also pro-
vides additional sensors for monitoring of the supply-air and
limit switch temperatures. This board is located in the main
unit control box. The inputs and outputs are summarized in
Table 90.
114
RF
Return Fan
RS
Rollout Switch
SAT
Supply Air Thermistor
SCB
Staged Gas Control Board
SEN
Sensor
SPT
Suction Pressure Transducer
STDU
Standard Tier Display Unit
TB
Terminal Block
TRAN
Transformer
U
Unloader
VAV
Variable Air Volume
VFD
Variable Frequency Drive
Terminal Block
Terminal (Unmarked)
Terminal (Marked)
Splice
Factory Wiring
Field Wiring
To indicate common potential
only, not to represent wiring.
To indicate factory-installed
option or accessory
INSTANCE JUMPER (SET TO 1)