ACCSY —
Accessory
ACC'Y
—
Accessory
AF
—
Airfoil
AN
—
Analog
APS
—
Air Pressure Switch
BM
—
Blower Motor
BR
—
Blower Relay
C
—
Compressor Contactor
CB
—
Compressor Circuit Breaker
CBT
—
Circuit Breaker, Transformer
CCB
—
Control Circuit Breaker
CCN
—
Carrier Comfort Network®
CCT
—
Cooling Coil Thermistor
CEM
—
Controls Expansion Module
CH
—
Crankcase Heater
CM
—
Combustion Motor
COMP
—
Compressor
CR
—
Control Relay
CSB
—
Current Sensor Board
CV
—
Constant Volume
DI
—
Digital Input
DPT
—
Discharge Pressure Transducer
ECB
—
Economizer Control Board
ECON
—
Economizer
EQUIP
—
Equipment
FU
—
Fuse
GND
—
Ground
GVR
—
Gas Valve Relay
HC
—
Heater Contactor
HIR
—
Heat Interlock Relay
HPS
—
High-Pressure Switch
HS
—
Hall Effect Sensor
HV
—
High Voltage
I
—
Ignitor
RED LED - STATUS
J1
J2
J3
J4
J5
J6
J7
ROOFTOP CONTROL BOARD (RCB) — The RCB has
additional inputs and outputs required for the control of the
unit. All units have an RCB board. See Fig. 27. The board has
9 inputs and 8 outputs. Details can be found in Table 88. The
RCB board is located in the main control box.
ECONOMIZER CONTROL BOARD (ECB) — The ECB
is used on size 075-105 units with high-capacity power exhaust
or return/exhaust fan. See Fig. 27. The ECB board sends a 4 to
20 mA signal to the VFD to control the exhaust fan speed. The
board also has inputs to sense the return fan cfm and supply fan
LEGEND FOR FIG. 15-25
IAQ
IDM
IFC
IFCB
IFM
IGC
IGV
IP
LEI
LEN
LS
MBB
MGV
MMC
MMR
MOD PE —
NEC
OA
OAQ
OAT
OD
OFC
OFM
OPT
PE
PEC
PECB
PEM
PL
PTC
RA
RAT
RCB
GREEN LED - LEN (LOCAL EQUIPMENT NETWORK)
CEPL130346-01 HK 50AA029 CE BO 430346
STATUS
LEN
Fig. 26 — Main Base Board (MBB)
—
Indoor Air Quality
—
Induced Draft Motor
—
Indoor Fan Contactor
—
Indoor Fan Circuit Breaker
—
Indoor Fan Motor
—
Integrated Gas Controller
—
Inlet Guide Vane
—
Internal Protector
—
Local Equipment Interface
—
Local Equipment Network
—
Limit Switch
—
Main Base Board
—
Main Gas Valve
—
Motormaster® Contactor
—
Motormaster Relay
Modulating Power Exhaust
—
National Electrical Code
—
Outdoor Air
—
Outdoor Air Quality
—
Outdoor-Air Thermostat
—
Outdoor
—
Outdoor Fan Contactor
—
Outdoor Fan Motor
—
Option
—
Power Exhaust
—
Power Exhaust Contactor
—
Power Exhaust Circuit Breaker
—
Power Exhaust Motor
—
Plug Assembly
—
Positive Temperature Coefficient
Power Reference
—
Return Air
—
Return Air Thermistor
—
Rooftop Control Board
YELLOW LED -
CCN (CARRIER COMFORT NETWORK)
J8
cfm. This board is located in the main control box. Input and
output assignments are summarized in Table 89.
STAGED GAS HEAT BOARD (SCB) — When optional
staged gas heat is used, the SCB board is installed and controls
additional stages of gas heat. See Fig. 28. The SCB also pro-
vides additional sensors for monitoring of the supply-air and
limit switch temperatures. This board is located in the main
unit control box. The inputs and outputs are summarized in
Table 90.
114
RF
—
Return Fan
RS
—
Rollout Switch
SAT
—
Supply Air Thermistor
SCB
—
Staged Gas Control Board
SEN
—
Sensor
SPT
—
Suction Pressure Transducer
STDU
—
Standard Tier Display Unit
TB
—
Terminal Block
TRAN
—
Transformer
U
—
Unloader
VAV
—
Variable Air Volume
VFD
—
Variable Frequency Drive
Terminal Block
Terminal (Unmarked)
Terminal (Marked)
Splice
Factory Wiring
Field Wiring
To indicate common potential
only, not to represent wiring.
To indicate factory-installed
option or accessory
INSTANCE JUMPER (SET TO 1)
J9
J10