ITEM
GEN.I
GENERAL INPUTS
FLT.S
Filter Status Input
G.FAN
Fan Request From IGC
REMT
Remote Input State
ENTH
Enth. Switch Read High ?
S.FN.S
Supply Fan Status Switch
FRZ.S
Freeze Status Switch
PP.SW
Plenum Press.Safety Sw.
DL.S1
Demand Limit Switch 1
DL.S2
Demand Limit Switch 2
DH.IN
Dehumidify Switch Input
FD.BK
COMPRESSOR FEEDBACK
HPS.A
Circ A High Press. Switch
HPS.B
Circ B High Press. Switch
CS.A1
Compressor A1 Feedback
CS.A2
Compressor A2 Feedback
CS.B1
Compressor B1 Feedback
CS.B2
Compressor B2 Feedback
STAT
THERMOSTAT INPUTS
G
Thermostat G Input
W1
Thermostat W1 Input
W2
Thermostat W2 Input
Y1
Thermostat Y1 Input
Y2
Thermostat Y2 Input
FIRE
FIRE-SMOKE INPUTS
FSD
Fire Shutdown Input
PRES
Pressurization Input
EVAC
Evacuation Input
PURG
Smoke Purge Input
REL.H
RELATIVE HUMIDITY
OA.RH
Outside Air Rel. Humidity
OA.EN
Outdoor Air Enthalpy
OA.DP
OutsideAir Dewpoint Temp
RA.RH
Return Air Rel. Humidity
RA.EN
Return Air Enthalpy
SP.RH
Space Relative Humidity
SP.EN
Space Enthalpy
AIR.Q
AIR QUALITY SENSORS
IAQ.I
IAQ - Discrete Input
IAQ
IAQ - PPM Return CO2
OAQ
OAQ - PPM Return CO2
DAQ
Diff.Air Quality in PPM
IQ.P.O
IAQ Min.Pos. Override
CFM
CFM SENSORS
O.CFM
Outside Air CFM
R.CFM
Return Air CFM
S.CFM
Supply Air CFM
D.CFM
Fan Track Control D.CFM
RSET
RESET INPUTS
SA.S.R
Supply Air Setpnt. Reset
SP.RS
Static Pressure Reset
4-20
4-20 MILLIAMP INPUTS
IAQ.M
IAQ Milliamps
OAQ.M
OAQ Milliamps
SP.R.M
SP Reset milliamps
DML.M
4-20 ma Demand Signal
EDR.M
EDT Reset Milliamps
ORH.M
OARH Milliamps
SRH.M
SPRH Milliamps
RRH.M
RARH Milliamps
SAC.M
SACFM Milliamps
SA.M.T
Supply Air CFM Trim (ma)
RAC.M
RACFM Milliamps
RA.M.T
Return Air CFM Trim (ma)
OAC.M
OACFM Milliamps
OA.M.T
Outside Air CFM Trim(ma)
BP.M
BP Milliamps
BP.M.T
Bldg. Pressure Trim (ma)
SP.M
SP Milliamps
SP.M.T
Static Press. Trim (ma)
*The display text changes depending on the remote switch configuration (Configuration
text will be "On" or "Off." If RM.CF is set to 1 (Occupied/Unoccupied Switch), then the display text will be "Occupied" or "Unoccupied." If RM.CF is set to 2 (Start/Stop),
then the display text will be "Stop" or "Start." If RM.CF is set to 3 (Override Switch), then the display text will be "No Override" or "Override."
APPENDIX A — LOCAL DISPLAY TABLES (cont)
MODE — INPUTS
EXPANSION
DRTY/CLN
ON/OFF
*
YES/NO
ON/OFF
ALRM/NORM
HIGH/LOW
ON/OFF
ON/OFF
ON/OFF
HIGH/LOW
HIGH/LOW
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ALRM/NORM
ALRM/NORM
ALRM/NORM
ALRM/NORM
HIGH/LOW
-2.0
-2.0
-2.0
-2.0
-2.0
RANGE
UNITS
%
dF
%
%
%
CFM
CFM
CFM
CFM
^F
ma
ma
ma
ma
ma
ma
ma
ma
ma
2.0
ma
2.0
ma
2.0
ma
2.0
ma
2.0
UNIT
RM.CF). If RM.CF is set to 0 (No Remote Switch), then the display
136
CCN POINT
WRITE STATUS
FLTS
forcible
IGCFAN
RMTIN
forcible
ENTH
forcible
SFS
forcible
FRZ
forcible
PPS
forcible
DMD_SW1
forcible
DMD_SW2
forcible
DHDISCIN
forcible
CIRCAHPS
CIRCBHPS
CSB_A1
CSB_A2
CSB_B1
CSB_B2
G
forcible
W1
forcible
W2
forcible
Y1
forcible
Y2
forcible
FSD
forcible
PRES
forcible
EVAC
forcible
PURG
forcible
OARH
forcible
OAE
OADEWTMP
RARH
forcible
RAE
SPRH
forcible
SPE
IAQIN
forcible
IAQ
forcible
OAQ
forcible
DAQ
IAQMINOV
forcible
OACFM
RACFM
SACFM
DELTACFM
SASPRSET
forcible
SPRESET
forcible
IAQ_MA
OAQ_MA
SPRST_MA
DMDLMTMA
forcible
EDTRESMA
OARH_MA
SPRH_MA
RARH_MA
SACFM_MA
SAMATRIM
RACFM_MA
RAMATRIM
config
OACFM_MA
OAMATRIM
config
BP_MA
BPMATRIM
config
SP_MA
SPMATRIM
config