3. DC charge coil resistance
• Disconnect the DC charge coil 1 leads.
• Connect the pocket tester.
• Measure the DC charge coil resistance.
DC charge coil resistance
Blue-Blue: 0.06 ~ 1.00 Ω
4. Inspect the rectifier continuity
• Disconnect the rectifier 1 leads.
• Connect the pocket tester (Ω × 1).
Check for continuity at following
points:
Pocket tester connecting point
(+) Red
(–) Black
Red terminal 2
Blue terminal
Blue terminal
4 Red terminal 2
Red terminal 2
Blue terminal
Blue terminal 5
Red terminal 2
Black terminal 3 Blue terminal 4
Blue terminal 4
Black terminal 3 NO
Blue terminal
Black terminal 3
Blue
terminal 5
Black terminal 3 NO
5. Inspect the DC circuit breaker continuity.
• Disconnect the DC circuit breaker 1
leads.
• Connect the pocket tester (Ω × 1).
Continuity:
"RESET" Position a → YES
"POP OUT" Position b → NO
CHARGING SYSTEM
LESS THAN
14.0 V
GOOD
Continuity
4 NO
YES
5 NO
YES
YES
5 YES
GOOD
4-12
L
1
L
OUT OF SPECIFICATION
Replace the DC charge coil.
4
1
L
2
R
L
B
2
3
5
1
5
NO GOOD
Replace the rectifier.
NO GOOD
Replace the circuit breaker.
+
ELEC
R × 1
SVU4210
B
R × 1
4
3
SVU4220
1
R × 1
SVU4230

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents