Operation Details
2. PROTECTION CONTROL FOR COOLING & SOFT DRY
a.
Anti-Freezing Control
When the temperature of the indoor heat exchanger becomes low, the compressor operating frequency is
reduced and stopped when the temperature falls to lower than 2°C continuously for 6 minutes. This is to
prevent freezing of indoor heat exchanger. When the temperature rises to 10°C or above, the compressor
restarts with 3 minutes. The compressor operating frequency will resume to normal when the temperature
reaches 14°C.
Indoor fan speed will increase when the temperature falls and it will resume to original speed when the
temperature increases to 14°C for 5 minutes continuously.
Indoor Heat
Exchanger
Temp. (°C)
Note: The above phenomenon occurs when the fan is running at Me+ or below.
b.
Anti-Dew Formation Control
When the following conditions occur for 20 minutes continuously, anti-dew formation is controlled:
1. Indoor intake air temperature is 24°C or above.
2. Outdoor air temperature is less than 30°C.
3. Remote control setting temperature is less than 25°C.
During anti-dew formation control, compressor operates at 55 Hz and vertical airflow direction blade moves
down slightly (as shown in Airflow Direction Control). Indoor fan speed increases by 1 rank if it is set at Low
or below or decreases by 2 ranks if it is set at Hi speed.
This control is cancelled immediately when either condition 1–3 as written above is changed, or remote
control setting temperature or fan speed is changed.
14
Free
Original
12
10
6
48 Hz
1 rank up
4
33 Hz
2
OFF
Comp.
Indoor Fan
When the temp. falls
Free
Original
48 Hz
33 Hz
1 rank up
OFF
Comp.
Indoor Fan
When the temp. rises