Panasonic GS-G90KE Service Manual page 35

Table of Contents

Advertisement

CS-G90KE
Operation Details
(b) Heating Operation
When the sleep button is pressed, the remote control setting temperature will decrease 2°C after 1 hour or
when the remote control setting temperature is reached. After another hour, 3°C will be decreased again.
* •
During sleep shift operation, indoor fan speed operates at Lo
13. DELAY ON TIMER CONTROL
When the Delay On Timer is set by using remote control, the unit will start to operate slightly earlier before the
set time, so that the room will nearly reach the set temperature by the On Timer set time.
60 minutes before the set time, the indoor fan operates at SLo and outdoor fan operates for 20 seconds to sample
the indoor intake air temperature and outdoor air temperature in order to determine the starting time for
preparatory operation. (The Power LED blinks during sampling.)
The time of the preparatory operation will start before the On Timer set time.
a. Cooling/Soft Dry
Indoor
intake
air temp
(°C)
30
25
14. AUTO RESTART CONTROL
If there is a power failure, operation will automatically be restarted when the power is resumed. It will start with
the previous operation mode and airflow direction. (Time Delay Safety Control is valid)
Auto Restart Control is not available when Timer or Sleep Mode is set.
Remote control
setting temperature
–2°C
When Sleep
button is pressed
1 hour
max 1 hour
Sleep mode shift
operation starts
15 min
10 min
5 min
30
35 (°C)
Outdoor air temp.
–3°C
8 hours
.
b. Heating
Indoor
intake
air temp
(°C)
15
35 min
5
45 min
Outdoor air temp.
– 41 –
All stop
25 min
0
5
(°C)