DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Trouble locating and clearing procedures (continued)
number
is the number of reports per hour (1 to 12)
Example input:
>REPORT
1
ON
6
If the response
is Link nn: Report interval set at:
is nn times per hour
is other than listed here
Determine if the report interval is correct.
If the interval
is correct
is wrong
To stop the C7BERT, type
>STOP
link_no
and press Enter.
where
link_no
is the number of the link (0 to 15) that the C7BERT runs on
Note: The STOP command overrides any preset stop time without
warning
If the response
is Link 1: C7BERT stopped
is with a display of test statistics
is other than listed here
Give the results to the person responsible for the next level of support.
If
the link stops on an NT9X77AA or
NT9X78BA/CA/DA/DB card, and you just ran a link
fault sectionalization. If instructions required you to
return the link to service
Running a C7BERT
Do
step 92
step 109
Do
step 82
step 90
Do
step 94
step 109