1-480 Trouble locating and clearing procedures (continued)
TOPS MP Operator complaint (standalone)
Clearing position failure - cannot reboot TPC
13
14
15
16
297-8021-544 Standard 14.02 May 2001
Determine if the hard disk drive light flashes.
If the hard disk drive light
flashes
does not flash
Examine the VDU display.
If
autobooting... continues to ap-
pear
the TPC reboots
any other message appears
Replace the hard disk drive. Refer to Card Replacement Procedures and
return to this step.
If
autobooting... continues to ap-
pear
autobooting... continues to ap-
pear and the original hard disk
drive is installed again
the TPC reboots
any other message appears
Replace the new hard disk drive with the original hard disk drive removed in
step 15. Refer to Card Replacement Procedures and return to step 18.
(continued)
Do
step 14
step 15
Do
step 18
step 25
Refer to the correct locating and
clearing trouble procedure for
the indicated trouble.
Do
step 16
step 17
step 25
Refer to the correct locating and
clearing trouble procedure for
the indicated trouble.