Ariston HS PREMIUM Technical Instructions page 13

Condensing wall thermal power plant
Table of Contents

Advertisement

Machine Translated by Google
Flue gas suction and exhaust pipe length table
Maximum length of suction /
discharge pipes (m)
Typology of
evacuation
24 EU
MAX
C13
C33
C43
B33
C13
C33
C43
C13
S1 = S2
C33
25/25
C43
S1 + S2
C53
C83
B23
S1 = air intake - S2 = exhaust gas
Diameter
HS PREMIUM
Pipes (mm)
30 EU
MAX
10
10
ø 60/100
10
10
25
25
ø 80/125
S1 = S2
25/25
S1 + S2
42
42
42
42
Smoke extraction / exhaust type
Combustion air from the environment
B23 Exhaust flue gas.
Ambient air suction
B33 Exhaust gas in a single or collective
chimney integrated in the building.
Ambient air suction.
ø 80/80
Combustion air from outside
C13 Exhaust flue gas through the
ø 80/80
external wall in the same
pressure range.
ø 80
C33 Exhaust gas exhaust and outside
air intake with external roof
terminal in the same pressure
range.
C43 Flue gas exhaust and air intake
through individual or collective
chimney integrated in the building.
C53 Exhaust gas exhaust and air
intake through the external wall
in the same pressure range.
C83 Flue gas exhaust through individual
or collective chimney integrated
in the building.
Suction air through the
external wall.
INSTALLATION
/
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

33007613300765

Table of Contents