Ariston HS PREMIUM Technical Instructions page 11

Condensing wall thermal power plant
Table of Contents

Advertisement

Machine Translated by Google
Condensation High
energy efficiency produces condensation, which must be eliminated. For
this purpose, use a plastic hose placed in such a way as to avoid any
stagnation of condensation inside the boiler. This hose must be connected
to an exhaust siphon with the possibility of visual inspection.
Observe the installation regulations in force in the country where
the installation is being carried out and comply with any
regulations of local authorities and public health bodies.
Check the installation of the condensate drain pipe:
- it must not be tight at the time of connection
- it does not have to form a swan neck
- Be sure to connect it to a vent.
To drain condensate, use only appropriate piping.
Condensate flow can reach 2 liters / hour. As the condensation
is acidic (pH close to 2), you will need to take all precautions
before proceeding.
CAREFUL!
THE ABSENCE OF WATER IN THE SIPHON CAUSES
EMISSIONS OF SMOKE EMPTYED INTO
AMBIENT AIR.
I
Hydraulic scheme
1
2
3
4
5
6
7
IAB
C
8 9
1.
Purjor manual
2. Heating tower probe
3. Burner
4. Safety valve 3 bar
5. Secondary plate heat exchanger
6. By-pass automat
7. Chiffon
8. Drain valve
9. Sanitary flow meter
10. Filling valve
11. Hydrometer
12. Heating circuit filter
13. Minimum load pressure switch
14. Recirculation pump with vent valve
15. Motorized 3-way valve
16. Heating return probe
17. Expansion vessel
18. Gas valve
19. Ignition / ignition electrode
20. Ventilator
INSTALLATION
20
19
18
17
16
15
14
13
12
FROM
10
11
/
11

Advertisement